■Setting the axis
Set the servo network configuration parameters "[Pr.141] IP address specification" and "[Pr.142] Multidrop number".
In general, set parameters
related to the servo amplifier
on the GX Works3 side in the
same way as for FX5-SSC-S.
■Setting the electronic gear
• When using a rotary MR-J5(W)-G motor, set the resolution of the electronic gear to the MR-J4(W)-B motor resolution (22
bit, or 4194304 pulse) instead of 26 bit (67108864 pulse).
The Motion module automatically overwrites the electronic gear of the servo amplifier parameters. For details, refer to the
following.
Page 108 Servo parameter setting value when using MR-J5(W)-G
APPX
110
Appendix 9 Setting Example for Motion Modules (FX5-SSC-G)
Downloaded from
ManualsNet.com
search engine
The IP address set in the CC-Link IE TSN
configuration can be selected (same as for
Motion Control Setting).
Displays the servo amplifier corresponding to the IP address.