Maintenance And Servicing; Warning; Maintenance Schedule - Beko CLEARPOINT 3eco S040 Original Installation And Operating Manual

Coalescing filter
Table of Contents

Advertisement

CLEARPOINT
®
3eco
coalescing filter

10. Maintenance and servicing

10.1 Warning

DANGER
DANGER
WARNING

10.2 Maintenance schedule

Maintenance
Cleaning work
Visual inspection
Replacing the float drain
Replace the filter element
Leak test
36 | 60
Pressurized system!
The risk of death or severe injuries exists in case of contact with fast or sudden exiting fluids 
or due to bursting system parts.
Carry out all maintenance and repair work only when the system is depressurized and
secure the system against unintentional pressurization.
Establish a safe area around the work area for all maintenance and repair work.
Before pressurizing the system, check and tighten all pipe connections.
Pressurize the system slowly.
Avoid pressure surges and high pressure differentials.
Mount all pipelines free of mechanical tension.
Compensate vibrations occurring in the pipeline network by using vibration dampers.
Securely pipe the inlet and outlet lines.
Use of incorrect replacement parts, accessories or materials!
The use of incorrect replacement parts, accessories or materials, as well as auxiliary and
operating materials, may pose a mortal danger or the danger of severe injuries. Functional
and operational disruptions may occur, as well as material damage.
Only use undamaged original parts, auxiliary and operating materials specified by the 
manufacturer in carrying out all work.
Only use materials permitted for the specific purpose and suitable tools in proper 
condition.
Only use cleaned pipelines free from dirt and corrosion.
Insufficient qualification!
If personnel have insufficient qualifications, this may result in accidents, personal injury 
and property damage as well as operating disruptions while working on the product or its
accessories.
All work on the product and accessories may only be carried out by professional service
technicians.
Installation and operation instructions
Interval
At regular intervals, depending on contamination
Weekly
Annually
Annually or at a differential pressure ≥ 0.4 bar (5.8 psig)
Recommendation: At the end of all assembly and
maintenance and repair work on the product

Advertisement

Table of Contents
loading

Table of Contents