16
Installation
NOTE
The following device has been tested and compatibility is
ensured. When you use the multiple ATM/POS device use the
recommended device.
-
AVE Products
VSI-PRO: Video serial interface
Regcom: RS-485 networker
Hydra: RS-485 to RS-232 converter
The installation and connection work should be done by
qualified service personnel or system installers and should
conform to all local codes.
3

Connecting Network

You can control and monitor the system via network. With
the remote control (monitoring), you can change the system
configuration or monitors the image via network. After the
installation, check the network settings for the remote control and
monitoring work.
Network connection
LAN connection
Connect the LAN port to an available 10/100/1000 base-T port with
a straight ethernet cable (not supplied). The NET indicator on the
front panel will be lit.
IP Camera connection
Connect the IP camera. After the installation, check the IP camera
settings on the setup menu.
Automatic network configuration
The DVR can automatically obtain and configure the network
interface via DHCP.
Manually configure network
The DVR may be manually configured by assigning an IP address,
subnet mask, gateway and DNS.
Broadband
Router
Service
NOTE
This unit can be supported IPv4 and IPv6 network.

Connecting RS-485 device

This DVR has two data terminals. Use this port to connect PTZ
cameras, DVRs or keypads (optional).
RS-485 Terminal
D - (DATA -)
Data Transmission/Reception
D + (DATA +)
Data Transmission/Reception
GND
Shield
Connecting the PTZ device
Connecting the PTZ serial communication lines to the
RS-485 terminal.
PTZ device connection
5~7 mm
PTZ units
(RS-485 type)
NOTE
When connecting lines, connect the "D -" of the DVR to "RX -"
of the PTZ unit and "D +" of the DVR to "RX +" of the PTZ unit
correctly.
Recommended initial data are 9600 Baud Rate, 8 Data bits,
1 Stop bit and No parity.
When connecting PTZ cameras to DVRs it is necessary to set
the setup menu for this unit according to the RS-485 settings
of the camera and DVRs.
Description
PTZ units
(RS-485 type)