Connecting Alarm Input And Alarm Output - LG LE5016 Series Owner's Manual

Hybrid digital video recorder
Hide thumbs Also See for LE5016 Series:
Table of Contents

Advertisement

Connecting LKD1000 controller
Connect the LKD1000 controller to control the DVR. (Refer to the
manuals of the LKD1000 controller for more details.) The LKD1000
controller has to be connected to the 2 (DATA 2) port as shown
illustration. If you connect the LKD1000 controller to the 1 (DATA 1)
port, the LKD1000 controller will not be activated.
LKD1000 controller connection
TX-
TX+
LKD1000 Controller
NOTE
Do not connect a PTZ camera and LKD1000 controller at the same
time to the D1 or D2 port. It may cause a malfunction.
Connecting Alarm Input and Alarm
Output
Alarm terminals are used to connect the alarm devices such as
sensors, door switches, etc.
Alarm Input
You can connect up to 16 alarm sensors (LE5008/LE4008: 8 alarm
sensors). Each alarm sensor should be connected with G (GND).
The signal state is adjustable to N/O (Normal Open) or N/C (Normal
Close) through the setup menu.
Sensor input connection
Alarm sensor
Terminal No.
1
2
3
4
G
5
6
7
8
G
9
10
11
12
G
13
14
15
16
G
Installation
Alarm sensor
Description
Sensor Input 1
Sensor Input 2
Sensor Input 3
Sensor Input 4
Ground
Sensor Input 5
Sensor Input 6
Sensor Input 7
Sensor Input 8
Ground
Sensor Input 9
Sensor Input 10
Sensor Input 11
Sensor Input 12
Ground
Sensor Input 13
Sensor Input 14
Sensor Input 15
Sensor Input 16
Ground
17
3

Advertisement

Table of Contents
loading

Table of Contents