Omron K3HB-P User Manual page 33

Digital indicators
Hide thumbs Also See for K3HB-P:
Table of Contents

Advertisement

● Event Inputs
A
B
C
D
E
1
2
3
4
5
6
Input control signals. The configuration is shown below.
Delays measurement until set time
S-TMR
expires.
Holds measurement value, maximum
HOLD
value, minimum value, and output
status.
Clears maximum value, minimum
RESET
value, and output status.
Sets a compensation value for the
COMPENSATION
measurement value.
Models with terminal blocks
<K35-1><K35-3>
Circuit Diagrams
<K35-1><K35-2> NPN Input Models
BANK (1,2,4)
S-TMR: D2
HOLD: D3
RESET: D4
COMPENSATION: D5
COM
<K35-3><K35-4> PNP Input Models
BANK (1,2,4)
S-TMR: D2
HOLD: D3
RESET: D4
COMPENSATION: D5
Models with connectors
<K35-2><K35-4>
1: N/C
3: HOLD
5: COMPENSATION
7: BANK4
9: BANK1
Applicable connector:
XG4M-1030 (OMRON)
12 V
4.7 KΩ
3.9 KΩ
3.9 KΩ
12 V 4.7 KΩ
COM
2.2 Using I/O
See page 5-34.
See page 5-48.
See page 5-33.
See page 5-61.
2: S-TMR
4: RESET
6: COM
8: BANK2
10: COM
2-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

K3hb-rK3hb-cK35-2

Table of Contents