Regency Fireplace Products Bellavista B41XTCE Owners & Installation Manual

Hide thumbs Also See for Bellavista B41XTCE:

Advertisement

Quick Links

Bellavista
Gas Fireplace
Bellavista B41XTCE Video
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
Tested by:
919-375c
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
®
B41XTCE
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
MODELS: B41XTCE-NG10
B41XTCE-LP10
12.13.16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bellavista B41XTCE and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Fireplace Products Bellavista B41XTCE

  • Page 1 Bellavista B41XTCE Installation Manual Gas Fireplace MODELS: B41XTCE-NG10 B41XTCE-LP10 Bellavista B41XTCE Video WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. appliance. - WHAT TO DO IF YOU SMELL GAS •...
  • Page 2: To The New Owner

    To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The Bellavista™ B41XTCE has been designed moment now to acquaint yourself with these instructions and the many features of your Regency ® Fireplace.
  • Page 3: Manufactured Mobile Home Requirements

    MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency ® to local codes. prohibited by local codes. This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
  • Page 4: Table Of Contents

    table of contents ..........6 venting arrangements ..........30 ............7 ........30 ...........31 Installation .....31 ....................32 Before You Start ..............................33 .............9 ....34 Locating Your Gas Fireplace .........9 ..............34 Clearances ..............10 ............34 Mantel Clearances............11 ............35 Mantel Leg Clearances..........12 .............35 Non-Combustible Requirements .........12 .........35 Framing ..............13 Gas Pipe Pressure Testing ..........35...
  • Page 5: Safety Decal

    safety decal review. NOTE: Regency ® COPY OF THE SAFETY DECAL Duplicate S/N DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION Certified for/Certifi e pour: é CANADA and U.S.A.
  • Page 6 requirements MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 7 dimensions UNIT DIMENSIONS 46-11/16" [1185mm] 38-3/8" [974mm] 46-11/16" 26-3/16" [1185mm] [664mm] 7-5/16" [185mm] 35" 3-1/4" [889mm] 38-7/16" [976mm] Regency Bellavista® B41XTCE-10 Gas Fireplace...
  • Page 8: Installation

    installation IMPORTANT MESSAGE 3) See general construction and assembly YOUNG CHILDREN SHOULD BE CARE- instructions. The appliance and vent should SAVE THESE FULLY SUPERVISED WHEN THEY ARE be enclosed. IN THE SAME AREA AS THE APPLI- INSTRUCTIONS ANCE. TODDLERS, YOUNG CHILDREN 4) This appliance must be connected to the AND OTHERS MAY BE SUSCEPTIBLE The B41XTCE-10 Gas Fireplace must be...
  • Page 9: Installation Checklist

    installation INSTALLATION This includes: 4) This appliance is Listed for bedroom CHECKLIST installations using the standard Remote 1) Locate appliance appliance for 15 minutes. codes before installation. 5) The B41XTCE Gas Fireplace are approved section for details. CAUTION: Any alteration to the product that causes sooting or carboning that results 6) We recommend that you plan your installation in damage is not the responsibility of the...
  • Page 10: Clearances

    installation CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: WARNING Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not NOT be recessed into combustible construction. system be installed only in accordance with these instructions. Clearance: Dimension Measured From:...
  • Page 11: Mantel Clearances

    installation MANTEL CLEARANCES Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
  • Page 12: Mantel Leg Clearances

    installation MANTEL LEG CLEARANCES 9 Side Wall (Measured from side of Fireplace Opening) Allowable mantel leg projection. Diagram 5 NON-COMBUSTIBLE REQUIREMENTS 46-11/16" [1186mm] NON-COMBUSTIBLE BOARD SUPPLIED W/UNIT 6" [152mm] No Combustible 11-5/8" [295mm] Materials in this Area NO FACING OR FINISHING MATERIAL IN THIS AREA 3-9/16"...
  • Page 13: Framing

    installation FRAMING Framing Dimensions Description B41XTCE Framing Width Corner Facing Wall Width Corner Facing Wall Width Framed Chase Ceiling - Rear Framed Chase Ceiling - Top Gas Connection Width Non-Combustible Drywall Header (or other (steel stud) facing) on edge Non-Combustible Header (steel stud) on edge Non-Combustible Facing...
  • Page 14: Framing & Finishing

    installation FRAMING & FINISHING 1. Frame in the enclosure for the unit with framing material. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed. 2. For exterior walls, insulate the enclosure to the same degree as the rest of the house; apply vapour barrier and drywall, as per local installation codes. (Do WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems in- issues.
  • Page 15 installation 7. Non-combustible material (ie. tile, slate, etc) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this will assure ease of glass door removal and access to the lower panel. NOTE: Non-combustible finishing materials may be of any thickness desired.
  • Page 16: Unit Assembly Prior To Installation

    installation UNIT ASSEMBLY PRIOR TO INSTALLATION BEFORE YOU START is moved into position. TOP STANDOFF ASSEMBLY top line up. Diagram 15 NAILING STRIPS 1. There are 8 (eight) side nailing strips and one top nailing strip available on the unit. One set of four (4) are for a clean finish installation, the other set are for a tile finish installation as they are set back 1/2"...
  • Page 17: Conversion To Top Vent

    installation CONVERSION TO TOP VENT Note: This conversion must be done prior to the unit being placed in position. Top Collar Assembly Kit Includes: Exhaust Assembly Restrictor Intake Collar Assembly Diagram 21 remove top insulation cover plate - by removing 2 screws as shown and discard. Swing door out from the bottom and lift up off...
  • Page 18 installation completely remove the insulation under the cover plate as shown and discard. over tighten. Diagram 29 Exhaust Assembly Diagram 25 Intake Collar Assembly IMPORTANT: Diagram 30 Diagram 26 13) Set vent restrictor accordingly - see next page. place the exhaust assembly into position Diagram 27 Diagram 28 18 |...
  • Page 19 installation VENTING INTRODUCTION draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney. VENT RESTRICTOR & BAFFLE INSTALLATION NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLED PRIOR TO OPTIONAL PANEL INSTALLATION. 2) Go to venting arrangements section to determine if a vent restrictor setting is required.
  • Page 20: Exterior Vent Termination Requirements

    installation EXTERIOR VENT TERMINATION REQUIREMENTS Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window 24"(60cm) 24"(60cm) from the center line of the terminal (check with the local code) 19-1/2"(50cm) 20"(51cm) Clearance to outside corner: with AstroCap XL Termination Cap.
  • Page 21: Cross Reference Chart Only

    installation 5" X 8" RIGID PIPE CROSS REFERENCE CHART ONLY 5” X 8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved. Description Selkirk ICC Excel...
  • Page 22 installation Description Selkirk ICC Excel Olympia Simpson Metal-Fab™ Ventis DV Direct Temp™ Direct Direct Vent Pro ® Sure Seal Attic Insulation Shield 12” 58DVA-IS VDV-AIS05 N/A from FPI Basic Horizontal Termination Kit (A ) 5DT-HKA TM-5HTK VDV-KW05 Horizontal Termination Kit (B) 58DVA-KHA 5DT-HKB TM-5HTK...
  • Page 23: Venting Arrangements For Horizontal Terminations

    installation VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS FLEX VENT OR RIGID PIPE 5" X 8" continuous Note: Must use optional rigid pipe adaptor (Part # 770-994) when using Rigid Pipe vent systems. • Maintain clearance to combustibles. • Horizontal vent must be supported every 3 feet. Horizontal (Feet) Horizontal (Feet) Max.
  • Page 24 installation HORIZONTAL TERMINATIONS FLEX VENT 5" X 8" Termination Locations" section. Regency ® Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615) or 10 foot Termination Kit (Part# 946-616) includes all the parts needed to install the B41XTCE with a either a top or rear vent. FPI Kit # Length Contains: spring spacers...
  • Page 25 installation HORIZONTAL TERMINATIONS RIGID PIPE 5" X 8" Horizontal Termination Top Vent - No Vertical Rise Rear Vent w/ Horizontal Termination Vinyl Siding Standoff (Optional) Horizontal Termination Wall Thimble Pipe Length Rigid Pipe Adaptor Pipe Length 90 Elbow Rigid Pipe Adaptor Diagram 42 Diagram 41 IMPORTANT...
  • Page 26: For Corner Installations

    installation HORIZONTAL TERMINATIONS ASTROCAP XL & RIGID REAR VENT KIT FOR CORNER INSTALLATIONS RIGID PIPE 5" X 8" Placement of the Unit into the Corner 3" 13" 770-994 946-625 Wall Thimble 90ml MillPac 91-11/16 Diagram 44 Diagram 43 IMPORTANT rear vent horizontal termination applications. Diagram 45 26 | Regency Bellavista®...
  • Page 27: Rigid Pipe Venting Systems

    installation RIGID PIPE VENTING SYSTEMS BASIC HORIZONTAL & VERTICAL TERMINATIONS Vertical Termination Storm Collar Horizontal Termination are: Vinyl Siding Elbow Flashing Standoff (Optional) Wall Thimble Astrocap Ceiling Firestop (946-623/P) Vertical Termination are: Wall Thimble Pipe Length Lengths of pipe to adequately Pipe Length penetrate roof Ceiling Firestop...
  • Page 28: For Horizontal Terminations

    installation VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS using one 90 elbows equal one 90 • Maintain clearances to combustibles as listed in "Clearances" section • Horizontal vent must be supported every 3 feet. • A wall thimble is mandatory for all horizontal terminations due to high temperatures. Horizontal (Feet) Restrictor 1-1/2 Open Set 3...
  • Page 29 installation HORIZONTAL TERMINATIONS TWO (2) 90 ELBOWS (RIGID PIPE 5" X 8") One 90 Option maximum total pipe length is 30 feet with minimum of 6 feet total Diagram 49 No Vent Restrictor Installed Lengths do not include elbow indicated. Must use rigid pipe adaptor #770-994.
  • Page 30: Venting Arrangements For Vertical Terminations

    installation VENTING ARRANGEMENTS FOR VERTICAL TERMINATIONS Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45 elbows equal to one 90 elbow. Maximum of four 45 elbows allowed. Horizontal (Feet) Restrictor 1-1/2 Open Set 3 Restrictor 2-1/2 Open Set 2 Restrictor 3-1/2 Open Set 1 Maximum 10 Centerline to Centerline...
  • Page 31: Vertical Terminations

    installation VERTICAL TERMINATIONS THREE (3) 90 ELBOWS (RIGID PIPE 5" X 8") One 90 Option maximum total pipe length is 30 feet with minimum of 6 feet total vertical No Vent Restrictor Installed Lengths do not include elbow indicated. Must use rigid pipe adaptor #770-994 Diagram 52 Regency Bellavista®...
  • Page 32: Horizontal Termination

    installation UNIT INSTALLATION WITH 7) Ensure that the pipe clearances to and elbows to the appliance adaptor and combustible materials are maintained HORIZONTAL TERMINATION Note: For best results and optimum Note: If installing termination on a vinyl 5" X 8" VENTING performance with each approved siding covered wall, a vinyl siding v e n t i n g s y s t e m , i t i s h i g h l y...
  • Page 33 installation UNIT INSTALLATION WITH NOTE: Horizontal sections must be sup- ASTROCAP XL ported at intervals not exceeding 3 HORIZONTAL feet (0.9 meter). (Flame picture and DIMENSIONS (946-623/P) TERMINATION in the liner). 5" X 8" VENTING 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the on top and bottom.
  • Page 34: Vertical Termination

    installation UNIT INSTALLATION WITH elbows. Ensure that all pipes and elbow con- VERTICAL TERMINATION and sealed. 5" X 8" VENTING MUST USE RIGID PIPE ADAPTOR #770-994 Feet Meters Diagram 62 NOTE: For best results and optimum perfor- mance with each approved venting system, it is highly recommended to apply “Mill- 1) Maintain the 2"...
  • Page 35: Pilot Adjustment

    installation PILOT ADJUSTMENT GAS PIPE B41XTCE -NG10 System Data PRESSURE TESTING For 0 to 4500 feet altitude The appliance must be isolated from the gas supply piping system by closing its individual Max. Input Rating to be touching the burner). testing of the gas supply piping system at Min.
  • Page 36 B41XT installation BRICK PANEL INSTALLATION BRICK PANEL INSTALLATION Must install one of the following: Brick Panels, Stainless Steel or Black Enamel Panels. Dangerous operating conditions may occur if the panels are not installed or if installed with broken panels. Handle with care. DO NOT FORCE INTO POSITION. 1) Unwrap the Brick Panels from the protective wrapping.
  • Page 37 B41XT installation OPTIONAL BLACK ENAMEL OPTIONAL BLACK ENAMEL PANEL INSTALLATION PANEL INSTALLATION Black Enamel Panels • Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. •...
  • Page 38 B41XT installation 4) Remove 1 screw (see inset A), position right side panel in fi rebox - 7) Carefully position and fi t the top bracket in place by ensuring the position panel clip in place and secure with 1 screw (see inset B). tabs of the bracket fi...
  • Page 39: Log Set Installation

    B41XT installation LOG SET INSTALLATION LOG SET INSTALLATION Installation of Brick or Black Enamel Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replac ed. Broken logs can interfere with pilot operation.
  • Page 40 B41XT installation 5) Place Log I on the left side of the burner, directly in front of Log A. 8) Slide the left side of Log H back until it touches the tab on the burner Position Log I so it fi ts into the pin on the burner as shown below. shown below.
  • Page 41 B41XT installation 11) Position Log E on top of Log H - fi t Log E into the pin on Log H as shown below. Diagram 13 14) Position Log C on top of Log G. Log C fi ts into the pin in Log G. as shown below.
  • Page 42 B41XT installation 16) Place the lava rocks on the burner in front of the logs as shown below. 17) Separate platinum embers and place on the front burner on and Be careful not to overlap the lava rock and ensure the burner ports around the lava rocks.
  • Page 43 installation AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS) AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS) An AC power adaptor is supplied with this appliance and may be installed as a constant power source for the SureFire system. NOTE: AC power adaptor is not required when using GTMF Remote with fan control module and must be disconnected. IMPORTANT: Recommend removing the 4-AA batteries in the SureFire receiver.
  • Page 44: Wiring Diagram

    installation WIRING DIAGRAM NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case the fan is installed at a later date. Proflame System Configuration 886 GTMF...
  • Page 45: Optional Fan Installation

    B41XTCE / B41XTE installation OPTIONAL FAN INSTALLATION FAN INSTALLATION Important: 120 Volt AC power is needed for the blower. The 6. Position the fan base with the motor end towards the rear of the receptacle box will be installed on the left hand side of the unit and fi...
  • Page 46 B41XTCE / B41XTE installation FAN INSTALLATION surfaces. Fan Power Cord TO REMOVE THE FAN the unit and plug in to electrical receptacle in unit as shown. Note: IMPORTANT: and housing using a soft brush nozzle. 919-425 08/21/14 46 | Regency Bellavista® B41XTCE-10 Gas Fireplace...
  • Page 47: Wiring Diagram With Optional Fan

    installation WIRING DIAGRAM WITH OPTIONAL FAN SureFire™ Switch Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Bellavista®...
  • Page 48: Optional Wall Thermostat Installation

    installation OPTIONAL WALL THERMOSTAT INSTALLATION A wall thermostat may be installed if desired. 4) Connect the other thermostat lead to male connector disconnected from Step1using a female spade connector - see picture below. Recommended: The Wall Thermostat should be mounted beside the Re- mote/Unit Receiver which comes standard with the appliance.
  • Page 49 B41XT installation OPTIONAL ACCENT LIGHT INSTALLATION OPTIONAL ACCENT LIGHT INSTALLATION 8) Remove the 2 screws securing the base tray - lift base tray up and Accent Light Assembly Kit out. Diagram 4a and 4b. 910-814 Plug wiring + gasket 910-997 Halogen Bulb 940-363 Amber Glass...
  • Page 50 B41XT installation 12) Install each light assembly from the underside of the fl oor of the 14) Install two light diffusers on to the base tray. fi rebox. Secure with 2 screws as shown below. 15) Secure diffusers onto base tray from the backside of the tray with 2 screws.
  • Page 51 installation B41XT LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT TO MAKE OUTLETS INDEPENDENT OF EACH OTHER Scheme - 1 Using Wall Switch only to turn lights ON/OFF. ELECTRICAL WORK MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN Ground Optional Lights Break Tab on Black (hot) side Clamp Connector Ground (Copper)
  • Page 52: Safety Screen

    installation FLUSH GLASS DOOR INSTALLATION Diagram 2 Diagram 1 Diagram 3 SAFETY SCREEN bottom and manoeuvre mesh out. Hooks on mesh barrier frame 52 | Regency Bellavista® B41XTCE-10 Gas Fireplace...
  • Page 53: Operating Instructions

    operating instructions OPERATING NORMAL OPERATING AERATION ADJUSTMENT INSTRUCTIONS SOUNDS OF The burner aeration is factory set but may need GAS APPLIANCES 1) Read and understand these instructions before operating this appliance. your gas appliance. This is perfectly normal due to the fact that there are various gauges and types Minimum Air Shutter Opening: of steel used within your appliance.
  • Page 54: Lighting Procedure

    operating instructions LIGHTING PROCEDURE IMPORTANT: The remote control system supplied with this appliance has seconds to light the main burner. please read the remote control operating 4. The unit will turn on. this remote control system. Option to download remote functions video with QR code below.
  • Page 55: Copy Of Lighting Plate Instructions

    operating instructions COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 56: Maintenance

    maintenance MAINTENANCE DOOR GLASS INSTRUCTIONS Your Regency ® system being exposed to cold weather. the burner and control compartment clean by dealers. Do not use abrasive materials. brushing and vacuuming at least once a year. CAUTION & WARNINGS: brush as the logs are fragile and easily damaged. 2) Clean appliance and door with a damp cloth product warranties.
  • Page 57: Accent Light Bulb Replacement

    B41XT maintenance ACCENT LIGHT BULB REPLACEMENT BULB REPLACEMENT 1) Shut off electrical and gas supply. 8) Remove the 2 screws securing the base tray - lift base tray up and out. Diagram 4a and 4b. 2) Remove the glass door - see instructions in manual. 3) Remove the logs, lava rock and vermiculite if installed.
  • Page 58: Valve Replacement

    maintenance VALVE REPLACEMENT INSTALLING VALVE 8) Remove the 2 screws securing the burner tray - lift burner tray up and out. Diagram 4a and 4b. 2) Reinstall the 14 hold down screws. 3) Remove the logs. the appropriate connections on the valve. Diagram 4a 4) Reinstall the rear log tray.
  • Page 59: Parts

    parts list MAIN ASSEMBLY Part # Description Part # Description 509-917 506-074 506-513 556-095 911-159 506-000 Mesh Guard 506-959 596-042F Top Relief Plate 910-997 Light Bulb 476-023 506-057 Flue Restrictor 502-061 Pilot Shield Calcium Silicate Board 911-012 919-375 Manual Spring Door Extension Ceramic Glass Door Frame Regency Bellavista®...
  • Page 60: Parts

    parts list BURNER ASSEMBLY Part # Description Part # Description 506-070 Rear Log Tray 506-062 Base Tray 911-012 DFC board 506-525 911-013 506-530 911-032 910-432 911-030 Fan Control Module 506-003 910-572 Remote Receiver 904-660 910-592 Remote Transmitter GTMF 904-431 506-901 506-531 506-902 506-904...
  • Page 61 notes Regency Bellavista® B41XTCE-10 Gas Fireplace...
  • Page 62: Warranty

    warranty Limited Lifetime Warranty FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products U.S., Inc. (for U.S. customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
  • Page 63 warranty At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof of purchase by you).
  • Page 64 warranty Limitations of Liability: The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty, express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. IN NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL DAMAGES OR DAMAGES TO PROPERTY.
  • Page 65 warranty Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 68 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Bellavista B41XTCE Video Regency® Bellavista®, AstroCap and SureFire™are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2016, FPI Fireplace Products International Ltd. All rights reserved.