Table of Contents

Advertisement

Quick Links

Regency Bellavista
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-810a
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
B41XT
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
Owners &
Installation Manual
MODELS: B41XT-NG
B41XT-LP
www.regency-fi re.com
Bellavista B41XT Video
12/14/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bellavista B41XT and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Fireplace Products Bellavista B41XT

  • Page 1 Installation Manual Gas Fireplace MODELS: B41XT-NG B41XT-LP www.regency-fi re.com Bellavista B41XT Video WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fi re or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life.
  • Page 2 Please take a moment now to acquaint yourself with these instructions and the many features of your ® Regency Fireplace. Bellavista Benefi ts Video Bellavista B41XT Video Regency Bellavista™ B41XT Gas Fireplace...
  • Page 3 MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE ® This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2009 / CSA 2.33-2009 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS 5" x 8" venting ..............32 SAFETY LABEL Unit installation with Vertical Termination ....33 5" x 8" venting ..............33 Copy of Safety Decal .............5 Gas Line Installation ............33 Pilot Adjustment ............34 REQUIREMENTS High Elevation .............34 Gas Pipe Pressure Testing ..........34 S.I.T.
  • Page 5: Safety Label

    SAFETY LABEL This is a copy of the label that accompanies each Bellavista™ B41XT Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency ® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 6: Requirements

    REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 7: Dimensions

    DIMENSIONS UNIT DIMENSIONS 23-1/4” (591mm) 13-3/16” (335mm) 46-11/16” (1186mm) 38-3/16” (970mm) 41-11/16” (1059mm) 43” (1092mm) 35” (889mm) 1” (25mm) Regency Bellavista™ B41XT Gas Fireplace...
  • Page 8: Important Message

    INSTALLATION IMPORTANT MESSAGE 11) Under no circumstances should this appliance YOUNG CHILDREN SHOULD BE be modifi ed. Parts that have to be removed CAREFULLY SUPERVISED WHEN SAVE THESE for servicing should be replaced prior to THEY ARE IN THE SAME ROOM AS operating this appliance.
  • Page 9: Installation Checklist

    INSTALLATION INSTALLATION This includes: 4) This appliance is Listed for bedroom CHECKLIST 1) Clocking the appliance to ensure the correct installations using the standard Remote fi ring rate (rate noted on label), after burning (millivolt thermostat system). Some areas appliance for 15 minutes. may have further requirements, check local 1) Locate appliance codes before installation.
  • Page 10: Clearances

    INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions. WARNING Caution Requirements Fire hazard is an extreme risk...
  • Page 11: Mantel Clearances

    INSTALLATION MANTEL CLEARANCES Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
  • Page 12: Mantel Leg Clearances

    INSTALLATION MANTEL LEG CLEARANCES 12-1/2” Side Wall (Measured from side of Fireplace Opening) Top View 4” 7” Allowable mantel leg projection. NON-COMBUSTIBLE REQUIREMENTS Non-combustible Header (steel stud) 48-3/4" on edge (1238mm) Non-combustible Non-combustible Material 41-3/4" (1060mm) 47-1/4" (1200mm) Framing Min. 3-1/2” Min.
  • Page 13: Framing

    INSTALLATION FRAMING Framing Dimensions Description B41XT Framing Width 47-1/4"(1200mm) Framing Height 49-1/2" (1257mm) O (Rear Vent) Framing Depth - Rear Vent 23-1/4" (591mm) O (Top Vent) Framing Depth - Top Vent 22-5/8" (575mm) Corner Facing Wall Width 60-1/4" (1530mm) Corner Facing Wall Width 85-3/16"...
  • Page 14: Finishing

    INSTALLATION FINISHING IMPORTANT FINISHING DETAIL NOTE: Important: Before placing unit into fi nal position - it is important to know the total Finishing materials such as tile, river rock, etc, must not protrude beyond thickness / height of fi nished hearth (tile, carpet, etc.) The base of the the front facing fl...
  • Page 15: Unit Assembly Prior To Installation

    INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION BEFORE YOU START The Top Facing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must be correctly positioned and attached before the fi replace is moved into position. TOP STANDOFF ASSEMBLY The top standoffs are shipped in a fl...
  • Page 16 INSTALLATION CONVERSION TO TOP VENT Note: This conversion must be done prior to the unit being placed in position. The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented. 3) From the inside of the fi...
  • Page 17 INSTALLATION 7) From the outside top of the fi rebox - remove the intake cover plate 10) From the inside of the fi rebox, place the exhaust assembly into by removing the 4 - 1/4" x 1/2 " screws. position as shown in Diagram 1 and secure with 10 - 1/4" x 1/2" screws (Diagram 2).
  • Page 18: Venting Introduction

    INSTALLATION VENTING INTRODUCTION The B41XT uses the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
  • Page 19: Exterior Vent Termination Requirements

    INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (61cm) 24"(60cm) 24"(60cm) from the center line of the terminal (check with the local code)
  • Page 20: 5" X 8" Rigid Pipe Chart

    INSTALLATION 5" X 8" RIGID PIPE CROSS REFERENCE CHART ONLY Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI. Description Selkirk ICC Excel Simpson Metal-Fab™ Direct Temp™ Direct Direct Vent Pro ®...
  • Page 21 INSTALLATION Description Selkirk ICC Excel Simpson Metal-Fab™ ® Direct Temp™ Direct Direct Vent Pro Sure Seal Attic Insulation Shield 12” 58DVA-IS N/A from FPI Basic Horizontal Termination Kit (A) 5DT-HKA Horizontal Termination Kit (B) 58DVA-KHA 5DT-HKB Vertical Termination Kit 58DVA-VHA 5DT-VKC High Wind Vertical Cap 58DVA-VCH...
  • Page 22: Venting Arrangements For Horizontal Terminations

    INSTALLATION VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS FLEX VENT OR RIGID PIPE 5" X 8" The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes. For horizontal terminations the Regency Direct Vent Flex System may be used for installations upto a maximum continuous vent length of 10ft (3.0m).
  • Page 23: Horizontal Terminations

    INSTALLATION HORIZONTAL TERMINATIONS FLEX VENT 5" X 8" These venting systems, in combination with the B41XT Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations"...
  • Page 24: Rigid Pipe 5" X 8

    INSTALLATION HORIZONTAL TERMINATIONS RIGID PIPE 5" X 8" Horizontal Termination Top Vent - No Vertical Rise • When venting with a 90° elbow directly off the unit Flex vent or approved Rigid Vent System • Max. 3 ft. horizontal run Rear Vent w/ Horizontal Termination •...
  • Page 25: Astrocap Xl & Rigid Rear Vent Kit

    INSTALLATION HORIZONTAL TERMINATIONS ASTROCAP XL & RIGID REAR VENT KIT FOR CORNER INSTALLATIONS RIGID PIPE 5" X 8" Designed for a minimum vent confi guration when using a rear vent Placement of the Unit into the Corner application with a horizontal termination in a corner installation. Back Top Corner of Unit to Wall 3"...
  • Page 26: Venting Arrangements

    INSTALLATION VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 (two 45 elbows equal one 90 elbow). • Maintain clearances to combustibles as listed in "Clearances" section • Horizontal vent must be supported every 3 feet. •...
  • Page 27: Rigid Pipe Venting Systems

    INSTALLATION RIGID PIPE VENTING SYSTEMS BASIC HORIZONTAL & VERTICAL TERMINATIONS Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal Vertical Terminal and vertical installations. Many items are offered in decorative black, as well as galvanized fi nish. Storm Collar The minimum components required for a basic Horizontal Termination are:...
  • Page 28: Three (3) 90 O Elbows (Rigid Pipe 5" X 8")

    INSTALLATION HORIZONTAL TERMINATIONS TWO (2) 90 ELBOWS (RIGID PIPE 5" X 8") One 90 elbow = Two 45 elbows. Option H + H1 W i t h t h e s e o p t i o n s , 0' Min.
  • Page 29 INSTALLATION VENTING ARRANGEMENTS FOR VERTICAL TERMINATIONS The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 elbows, with Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45 elbows equal to one 90 elbow.
  • Page 30: Vertical Terminations

    INSTALLATION VERTICAL TERMINATIONS THREE (3) 90 ELBOWS (RIGID PIPE 5" X 8") One 90 elbow = Two 45 elbows. Option H + H1 V + V1 With these options, max. 0' Min. 2' Max. 2' Min. total pipe length is 30 feet 1' Min.
  • Page 31: Unit Installation With Horizontal Termination

    INSTALLATION UNIT INSTALLATION 5) Assemble the desired combination of pipe 7) Ensure that the pipe clearances to and elbows to the appliance adaptor and combustible materials are maintained WITH HORIZONTAL twist-lock for a solid connection. (Diagram 5). Install the termination cap. TERMINATION Note: For best results and optimum Note: If installing termination on a vinyl...
  • Page 32: Unit Installation With Horizontal Termination

    INSTALLATION UNIT INSTALLATION NOTE: Horizontal sections must be sup- ASTROCAP XL ported at intervals not exceeding 3 WITH HORIZONTAL feet (0.9 meter). (Flame picture and DIMENSIONS (946-623/P) performance will be affected by sags TERMINATION in the liner). 5" X 8" VENTING 4) Separate the 2 halves of the wall thimble and (Flex Vent Systems) securely fasten the one with the tabs to the...
  • Page 33: Unit Installation With Vertical Termination

    INSTALLATION UNIT INSTALLATION 4) Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow con- WITH VERTICAL nections are in the fully twist-locked position and sealed. TERMINATION 5" X 8" VENTING (Rigid Vent Systems) Diagram 4 MUST USE RIGID PIPE Roof Pitch Minimum Vent Height...
  • Page 34: Pilot Adjustment

    INSTALLATION GAS PIPE PILOT ADJUSTMENT B41XT -NG System Data PRESSURE TESTING Periodically check the pilot fl ames. Correct Conversion Kit # fl ame pattern has three strong blue fl ames: The appliance must be isolated from the gas 1 fl owing around the thermopile, 1 around For 0 to 4500 feet altitude supply piping system by closing its individual Burner Inlet Orifi...
  • Page 35: Brick Panel Installation

    INSTALLATION BRICK PANEL INSTALLATION Must install one of the following: Brick Panels, Stainless Steel or Black Enamel Panels. Dangerous operating conditions may occur if the panels are not installed or if installed with broken panels. Handle with care. DO NOT FORCE INTO POSITION. 1) Unwrap the Brick Panels from the protective wrapping.
  • Page 36: Optional Panel Installation

    INSTALLATION OPTIONAL STAINLESS STEEL / BLACK ENAMEL PANEL INSTALLATION Before installation, panels must be handled and cleaned as per instructions noted below: Stainless Steel Panels Black Enamel Panels • Stainless panels must be inspected for scratches and dimples prior • Black Enamel panels must be inspected for scratches and dimples to installation.
  • Page 37 INSTALLATION 4) Remove 1 screw (see inset A), position right side panel in fi rebox - 7) Carefully position and fi t the top bracket in place by ensuring the position panel clip in place and secure with 1 screw (see inset B). tabs of the bracket fi...
  • Page 38: Log Set Installation

    INSTALLATION LOG SET INSTALLATION Installation of Brick or Stainless Steel / Black Enamel Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation.
  • Page 39 INSTALLATION 5) Place Log I on the left side of the burner, directly in front of Log A. 8) Slide the left side of Log G back until it touches the tab on the burner Position Log I so it fi ts into the pin on the burner as shown below. shown below.
  • Page 40 INSTALLATION 11) Position Log E on top of Log G - fi t Log E into the pin on Log G as shown below. 14) Position Log C on top of Log H. Log C fi ts into the pin in Log H. as shown below.
  • Page 41 INSTALLATION 16) Place the lava rocks on the burner in front of the logs as shown below. 17) Separate platinum embers and place on the front burner on and Be careful not to overlap the lava rock and ensure the burner ports around the lava rocks.
  • Page 42: Optional Wall Thermostat

    INSTALLATION Optional Optional Optional WALL THERMOSTAT REMOTE CONTROL WALL SWITCH ® Use the Regency Remote Control Kit approved 1) Run the supplied 10' of wire through the right A wall thermostat may be installed if desired, con- for this unit. Use of other systems may void or left side gas inlet opening.
  • Page 43: Optional Fan Installation

    INSTALLATION OPTIONAL FAN INSTALLATION Important: 120 Volt AC power is needed for the fan switch and blower. 6) Position the fan base with the motor end towards the rear of the The receptacle box will be installed on the left hand side of the unit fi...
  • Page 44 INSTALLATION 10) Slide the the Fan control box under the 9) Slide the thermodisc/cover assembly onto the bracket clip on the clip on the fl oor of the fi rebox. left underside of the fi rebox. Ensure that no wires will touch hot surfaces.
  • Page 45: Aeration Adjustment

    INSTALLATION AERATION ADJUSTMENT The burner aeration is factory set but may need CAUTION: Carbon will be produced if air shutter adjusting due to either the local gas supply or is tightly closed. altitude. Open the air shutter for a blue fl ame or close for a more yellow fl...
  • Page 46: Wiring Diagram For Ng And Lp Units

    INSTALLATION WIRING DIAGRAM FOR NG AND LP UNITS Optional Fan Ground Star washer #8 Ground Lug (for mobile home) Neutral Green Live Ground 120V AC 60 Hz Black Pilot Assembly Minimum Convection Lockwasher Rotary Speed Air Temp. Switch Control ground wire DC Spark Ground (To THTP)
  • Page 47 INSTALLATION 584 Proflame GT Series Feature Sheet Indicates Included Feature Note 1 ~ Profl ame Flame Modulator for GTM & GTMF Remote Controls are sold seperately. Choice of NG or LP fl ame modulator (to match unit fuel type). See Regency Retail Price pages for complete details Note: Regency Profl...
  • Page 48: Optional Accent Light Installation

    INSTALLATION OPTIONAL ACCENT LIGHT INSTALLATION 9) Remove the 2 screws securing the base tray - lift base tray up and B41XT Accent Light Assembly Kit out. Diagram 4a and 4b. 910-814 Plug wiring + gasket 910-997 Halogen Bulb 940-363 Amber Glass Light Assembly Includes gaskets (x 2) 918-864...
  • Page 49 INSTALLATION 13) Install each light assembly from the underside of the fl oor of the 15) Install two light diffusers on to the base tray. fi rebox. Secure with 2 screws as shown below. 16) Secure diffusers onto base tray from the backside of the tray with 2 screws.
  • Page 50: Flush Glass Door Installation

    INSTALLATION FLUSH GLASS DOOR INSTALLATION The standard fl ush door comes with a black frame. To install the frame, Be careful that the glass gasket does not roll up; there must be a gap simply hook the top door fl ange onto the top of the unit and swing the between the gasket and the door lip to ensure that the door sits securely door towards the unit, see Diagram 1.
  • Page 51: Louvers / Flush Panel Installation

    INSTALLATION LOUVERS / FLUSH PANEL INSTALLATION 4. Fasten the hinges to the louver / fl ush panel with 3 screws each as 1. To install the lower louver or fl ush panel - line up the 2 hinges with shown below. the brackets in the unit as shown below.
  • Page 52: Full Screen Arch Door And Frame Installation

    INSTALLATION FULL SCREEN ARCH DOOR AND FRAME INSTALLATION 1) Remove glass door (refer to glass door removal in the manual). 4) Slide bracket into slot on the back of the full screen door frame. See diagram 3. 2) Install 4 Phillips screws (supplied with packaging) to the inside 5) Lift screen doors off of door frame to reduce the weight during walls of the unit (see Diagram 1 for locations).
  • Page 53 INSTALLATION 7) Secure the bracket installed in Step 4 - to the inside of the fi rebox in 11) Flip the hinges down to 90° - line up the lower mesh screen door the same location and with the same screws from Step 3 . as shown below.
  • Page 54 INSTALLATION 14) To install the top panel - line up the 2 tabs on the panel with the corresponding bracket clip on the inside top of the unit and slide into place (see below). 16) Re-hang the screen doors. Location of bracket clips in unit. 15) The full screen doors are stabilized by 2 magnets which are attached to a bracket.
  • Page 55: Operating Instructions

    OPERATING INSTRUCTIONS LIGHTING OPERATING NORMAL OPERATING PROCEDURE SOUNDS OF INSTRUCTIONS GAS APPLIANCES IMPORTANT 1) Read and understand these instructions To ignite or reignite the pilot, you before operating this appliance. It is possible that you will hear some sounds from your gas appliance.
  • Page 56: Copy Of Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1.
  • Page 57: Maintenance Instructions

    MAINTENANCE MAINTENANCE GLASS GASKET 3) Check for evidences of excessive condensation, such as water droplets forming INSTRUCTIONS in the inner liner, and subsequently dripping If the glass gasket requires replacement use a out the joints, Continuous condensation can tadpole glass gasket (Part # 936-155). cause corrosion of caps, pipe, and fi...
  • Page 58: Accent Light Bulb Replacement

    MAINTENANCE ACCENT LIGHT BULB REPLACEMENT 1) Shut off electrical supply. 9) Remove the 2 screws securing the base tray - lift base tray up and out. Diagram 4a and 4b. 2) Remove Full Screen Door and bottom Louver if installed. 3) Remove the glass door - see instructions in manual.
  • Page 59: Valve Replacement

    MAINTENANCE VALVE REPLACEMENT 8) Remove the 2 screws securing the burner tray - lift base tray up and out. Diagram 4a and 4b. 1) Shut off the gas and electrical supply. 2) Remove the louvers 3) Open the fl ush door and remove the door. Diagram 4a 4) Remove the logs.
  • Page 60: Parts List

    PARTS LIST MAIN ASSEMBLY Part # Description Part # Description 506-086 Top Insulation Plate 506-917 Fan Assembly 506-074 Top Insulation 910-215/P Fan Motor (120 Volts) 506-513 Flue Collar Outer Assembly 432-966 Fan Switch Assy (120 Volts) 506-000 Exhaust Gasket 910-813 Power Cord (120 Volts) 556-095 Flue Collar Gasket...
  • Page 61: Burner Assembly

    PARTS LIST BURNER ASSEMBLY Part # Description Part # Description 506-070 Rear Log Tray 904-660 Orifi ce #30 NG 904-431 Orifi ce #49 LP 506-525 B41XT Burner Assembly NG 506-531 B41XT Grate Assembly 506-574/P Valve Assembly - NG 506-576/P Valve Assembly - LP 910-568 Valve NG/LP SIT High/Low 820 506-003...
  • Page 62: Accessories

    PARTS LIST ACCESSORIES Part # Description 506-946 3-Sided Finishing Trim 506-920 Louvers Set - Black 506-924 Louvers Set - Gold / Black 506-926 Louvers Set - Steel / Black 506-916 Black Flush Panels - Set 506-901 Brick Panels - Standard Brown 506-902 Brick Panels - Standard Red 506-905...
  • Page 63: Warranty

    WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly ® before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
  • Page 64 Register your Regency warranty online ® www.regency-fi re.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notifi cation of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

Bellavista b41xt-ngBellavista b41xt-lp

Table of Contents