Venting Kits; Install Vent System - Maytag Commercial MEDP575GW Installation Instructions Manual

Electric dryer 27" wide models – u.s.a. only
Table of Contents

Advertisement

Venting Kits

For more information, call 1-800-344-1274, or visit us
at www.maytagreplacementparts.com.
Part Number
Descriptions
8171587RP
0"–5" Metal vent periscope
4396037RP
0"–18" Metal vent periscope
4396011RP
18"–29" Metal vent periscope
4396014
29"–50" Metal vent periscope
4392892
In-wall metal DuraVent™ periscope
279818
4-way vent kit – white
W10186596
4-way vent kit – universal grey
4396028
Sure Connect™ venting kit
(over-the-top installation)
4396009RP
5' Universal connect vent, fl exible dryer venting
4396010RP
6' SecureConnect™ vent, fl exible dryer venting
4396013RB
Dryer vent installer's kit
4396033RP
5' fl exible dryer venting with clamps
4396727RP
8' fl exible dryer venting with clamps
4396004
Dryer offset elbow
4396005
Wall offset elbow
4396006RW
DuraSafe™ close elbow
4396007RW
Through-the-wall vent cap
4396008RP
4" steel dryer venting clamps – 2 pack
8212662
Flush mounting louvered vent hood, 4"
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path:
Select route that will provide straightest and most direct
path outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specifi ed
in Vent System Chart. Exhaust systems longer than those
specifi ed will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
The Vent System Chart provides venting requirements that
will help achieve best drying performance.
Vent System Chart
Number of
Type
90° turns
of vent
or elbows
Rigid metal
0
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
NOTE: Side and bottom exhaust installations have a 90º turn
inside the dryer. To determine maximum exhaust length, add
one 90º turn to the chart.

Install Vent System

1.
Install exhaust hood
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
Box/louvered
Angled
hoods
hoods
58 ft. (17.7 m)
64 ft. (20 m)
54 ft. (16.5 m)
48 ft. (14.6 m)
44 ft. (13.4 m)
38 ft. (11.6 m)
35 ft. (10.7 m)
29 ft. (8.8 m)
27 ft. (8.2 m)
21 ft. (6.4 m)
12" min.
(305 mm)
12" min.
(305 mm)
15