Maytag Commercial MEDP575GW Installation Instructions Manual page 9

Electric dryer 27" wide models – u.s.a. only
Table of Contents

Advertisement

4-Wire Power Supply Cord Connection
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
4-wire receptacle
(NEMA type 14-30R)
Spade terminals
with upturned ends
1.
Prepare to connect neutral ground
wire and neutral wire
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
2.
Connect neutral ground wire
and neutral wire
Connect neutral ground wire (E) and neutral wire (white or
center) (C) of power supply cord under center terminal block
screw (B). Tighten screw.
4-prong plug
Ring terminals
E
A
B
E
C
3.
Connect ground wire
A
F
Connect ground wire (F) (green or bare) of power supply cord
to external ground conductor screw (A). Tighten screw.
4.
Connect remaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to "Venting Requirements."
3-Wire Power Supply Cord Connection
IMPORTANT: Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
3-wire receptacle
(NEMA type 10-30R)
Spade terminals
with upturned ends
3-prong plug
Ring terminals
9