VENTING REQUIREMENTS

WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Following these venting requirements will minimise ducting
air noise.
Exhaust air must not be discharged into a flue for
exhausting fumes from appliances burning gas or other
fuels, including open fires (i.e. available airflow into
the room should match airflow out from the room).
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed
space of a building. Only rigid or flexible metal vent shall
be used for exhausting.
Do not use an exhaust hood with a magnetic latch.
102 mm (4") heavy, metal exhaust vent
Only a 102 mm (4") heavy, metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent:
(Acceptable only if accessible to clean)
Must be fully extended and supported in final dryer location.
Remove excess to avoid sagging and kinking that may
result in reduced airflow and poor performance.
Do not install in enclosed walls, ceilings, or floors.
The total length should not exceed 2.4 m (7
An exhaust hood should cap the vent to keep rodents
and insects from entering the building.
NOTE: If using an existing vent system, clean lint from
entire length of the system and make sure exhaust hood is
not plugged with lint. Replace plastic or metal foil vents with
rigid metal or flexible metal vents. Review "Vent System Chart"
and if necessary, modify existing vent system to achieve best
drying performance.
12
Elbows:
Clamps:
102 mm
(4")
ft.).
3
4
45° elbows provide better airflow than 90° elbows.
Good
Plan installation to use the fewest number of elbows
and turns.
Allow as much room as possible when using elbows
or making turns. Bend vent gradually to avoid kinking.
Vent outlet is located at the center of the bottom dryer back.
The vent can be routed up, down, left, right, behind the
dryer, or straight out the back of the dryer.
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with
screws or other fastening devices that extend into interior
of duct and catch lint. Do not use duct tape.
Better