Power Supply
Model: PWS-407P-1R (x2), 80 Plus level Platinum
Total Output Power: 400W
AC Input Voltages: 100-240V, 200-240V
Rated Input Frequency: 50-60Hz
Max: 33A & Min: 0.5A
5V SB:
Max: 3A / Min: 0A
Output Type:
Gold Finger Connector Mating with Molex 45984-4343
Operating Environment
Operating Temperature: 0º to 45º C (32º to 113º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55032 Class A, EN 61000-3-2/3-3, CISPR 32 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,
EN 61000-4-8, EN 61000-4-11)
Other: VCCI-CISPR 32 and AS/NZS CISPR 32
Environmental: Directive 2011/65/EU, Deligated Directive (EU) 2015/863,and Directive 2012/19/EU
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe)
Perchlorate Warning
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products
containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See
hazardouswaste/perchlorate"