Page 2
State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
Page 3
If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Warnings Special attention should be given to the following symbols used in this manual.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Contents Chapter 1 Introduction 1.1 Overview ..........................8 1.2 Unpacking the System .......................10 1.3 System Features ........................11 1.4 Chassis Features .......................13 Power Button/LED ......................13 Front Features ........................14 Chassis Rear ........................15 1.5 Motherboard Layout ......................16 Quick Reference Table ......................17 Chapter 2 Server Installation 2.1 Overview ..........................20 2.2 Preparing for Setup ......................20...
Page 5
Preface Memory Support ......................29 DIMM Module Population Configuration ................29 DIMM Module Population Sequence ................30 DIMM Installation ......................31 Severboard Battery ......................32 3.4 Chassis Components ......................33 Storage Drives ........................33 Drive Carriers .........................33 Installing Hot-Swappable Hard Drives ................34 Installing Fixed Internal Drives ..................36 System Fans ........................37 Installing the Air Shroud ....................38 Checking the Server Air Flow ..................39...
Page 6
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual 6.5 IPMI ........................... 96 6.6 Security ..........................100 6.7 Boot ..........................103 6.8 Save & Exit ........................105 Appendix A Standardized Warning Statements for AC Systems Appendix B UEFI BIOS Recovery Instructions Appendix C System Specifications...
Page 7
Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Chapter 1 Introduction 1.1 Overview This chapter provides a brief outline of the functions and features of the 1019D-FHN13TP, 1019D-4C-FHN13TP, 1019D-14CN-FHN13TP, and 1019D-16C-FHN13TP servers. It is based on the X11SDW-4C-TP13F, X11SDW-8C-TP13F, X11SDW-14CNT-TP13F, and X11SDW-16C-TP13F motherboards and the SC513BTS-350WB and SC513BTS-505WB chassis.
Page 9
Chapter 1: Introduction Motherboard Model Variation Table Motherboard X11SDW-4C-TP13F X11SDW-8C-TP13F X11SDW-14CNT-TP13F X11SDW-16C-TP13F Model Name Processor D-2123IT D-2146NT D-2177NT D-2183IT Name Number of Cores Number of Threads Processor Base 2.20GHz 2.30GHz 1.90GHz 2.20GHz Frequency Max Turbo 3.00GHz 3.00GHz 3.00GHz 3.00GHz Frequency SoC Max TDP 105W 100W...
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual In addition to the motherboards and chassis, several important parts that are included with the system are listed below. Main Parts List Description Part Number Quantity PWS-350-1H (for 1019D-FHN13TP or 1019D-4C-FHN13TP) Power supply module PWS-505P-1H (for 1019D-14CN-FHN13TP or 1019D-16C-FHN13TP) Backplane...
Chapter 1: Introduction 1.3 System Features The table below is an overview of the main features of the 1019D-FHN13TP, 1019D-4C-FHN13TP, 1019D-14CN-FHN13TP, and 1019D-16C-FHN13TP servers. System Features Motherboards X11SDW-8C-TP13F for 1019D-FHN13TP X11SDW-4C-TP13F for 1019D-4C-FHN13TP X11SDW-14CNT-TP13F for 1019D-14CN-FHN13TP X11SDW-16C-TP13F for 1019D-16C-FHN13TP Chassis SC513BTS-350WB for 1019D-FHN13TP and 1019D-4C-FHN13TP SC513BTS-505WB for 1019D-14CN-FHN13TP and 1019D-16C-FHN13TP Intel Xeon D-2146NT for 1019D-FHN13TP (in socket FCBGA2518)
Page 12
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual System Features Power 1019D-FHN13TP and 1019D-4C-FHN13TP: 350W AC 80Plus Platinum level power supply 1019D-14CN-FHN13TP and 1019D-16C-FHN13TP: 500W AC 80Plus Platinum level power supply Cooling 1019D-FHN13TP and 1019D-4C-FHN13TP: Four 40mm PWM fans, plus an option for two more fans 1019D-14CN-FHN13TP and 1019D-16C-FHN13TP: Six 40mm PWM fans Input/Output Nine RJ45 Gigabit Ethernet LAN ports (one for Ethernet management port);...
Chapter 1: Introduction 1.4 Chassis Features Power Button/LED The main power switch is used to apply or remove power from the power supply to the server. Turning off system power with this button removes the main power, but maintains standby power.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Front Features The illustration below shows the features included on the front of the chassis. Figure 1-2. Chassis Front View Front Chassis Features Item Feature Description Control Panel Front control panel with LEDs and buttons (see preceding page) Drives Two hot-swap 2.5"...
Chapter 1: Introduction Chassis Rear The illustration below shows the features included on the rear of the chassis. Kensington Lock Power Input Figure 1-4. Rear View...
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual 1.5 Motherboard Layout Below is a layout of the X11SDW-4C/8C/14CNT/16C-TP13F motherboard with jumper, connector, and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information, and jumper settings, refer to Chapter 4. LAN12/13 LAN1 LAN10/11...
Chapter 1: Introduction Quick Reference Table Jumper Description Default Setting M.2 SMBus Enable/Disable Pins 1-2 (Enabled) JBM1 Disable IPMI Shared LAN Pin 1-2 Open (Enable) JBM2 Disable Dedicated IPMI/Shared LAN Pin 1-2 Open (Enable) JBT1 CMOS Clear Open: Normal Closed: Clear CMOS JI2C1/JI2C2 SMB to PCI-E Slots Enable/Disable Pins 2-3 (Disabled)
Page 18
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Connector Description JNVI2C1 Non-volatile Memory (NVMe) I C Header JPH1 4-pin HDD Power Connector JPI2C1 Power I2C System Management Bus (Power SMB) Header JPV1 12V 8-pin DC Power Connector (Required to provide extra power to the CPU, or as alternative power for special enclosure when the 24 pin ATX power is not in use) JPW1 GPU Power Connector...
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with system memory etc., refer to Chapter 4 for details on installing those specific components.
Chapter 2: Server Installation • Always make sure the rack is stable before extending a server or other component from the rack. • You should extend only one server or component at a time - extending two or more simul- taneously may cause the rack to become unstable.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Chapter 2: Server Installation 2.3 Identifying the Sections of the Rack Rails The chassis package includes two rack rail assemblies in the rack mounting kit. Each as- sembly consists of two sections: an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Inner Rails The inner rails are pre-attached to the chassis, but should the need arise to remove them, reinstallation of the rails is simple and can be accomplished with a screwdriver. Installing the Inner Rails 1. Place the inner rail on the side of the chassis aligning the hooks of the chassis with the inner rail holes.
Chapter 2: Server Installation Outer Rails Outer rails attach to the rack and hold the server in place. The outer rails for the chassis extend between 30 inches and 33 inches. Installing the Outer Rails to the Rack 1. Attach the short bracket to the outside of the long bracket. Align the pins of the rail with the slides.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual 2.4 Installing the Chassis into the Rack 1. Confirm that the chassis includes the inner rails and rail extensions. Also, confirm that the outer rails are installed on the rack. 2. Align the chassis rails with the front of the rack rails. 3.
Chapter 3: Maintenance and Component Installation Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual 3.2 Accessing the System Removing the Chassis Cover 1. Power down the system as described in Section 3.1. 2. Remove the six screws that are securing the top cover to the chassis. 3. Slide the cover back toward the rear of the chassis. 4.
3.3 Motherboard Components Memory Note: Check the Supermicro website for recommended memory modules. Memory Support T h e X 11 S D W- 4 C - T P 1 3 F, X 11 S D W- 8 C - T P 1 3 F, X 11 S D W- 1 4 C N T- T P 1 3 F, a n d X11SDW-16C-TP13F support up to 256GB of ECC RDIMM or 512GB of ECC LRDIMM DDR4 memory in four memory slots.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual DIMM Module Population Sequence When installing memory modules, the DIMM slots should be populated in the following order: DIMMA1, DIMMB1, then DIMMD1, DIMME1. • Always use DDR4 DIMM modules of the same type and speed. • Mixed DIMM speeds can be installed.
Chapter 3: Maintenance and Component Installation DIMM Installation Insert the desired number of DIMMs into the memory slots based on the recommended population table on the previous page. Installing Memory Begin by removing power from the system as described in Section 3.1. 1.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Severboard Battery Caution: There is a danger of explosion if the onboard battery is installed in the wrong orientation with reversed polarities. This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032). Dispose of used batteries according to the manufacturer's instructions.
Storage Drives The system supports two hot-swap 2.5" drives and two internal 2.5" solid-state disk drives. Note: Enterprise level drives are recommended for use in Supermicro servers. For information on recommended HDDs, visit the Supermicro website product pages at https://www.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Installing Hot-Swappable Hard Drives The chassis supports two 2.5" hot-swappable hard disk drives. Only enterprise-level hard drives are recommended. Note: The hard drives in your chassis may look slightly different than the ones shown in this manual.
Page 35
Chapter 3: Maintenance and Component Installation 3. Install the drive into the drive tray and secure it with screws. Screws Screws Figure 3-6. Installing Storage Drives 4. Lock the drive tray and place into chassis. Lock Figure 3-7. Installing the Hot Swappable Drive...
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Installing Fixed Internal Drives Installing 2.5" Drives to the Chassis Floor 1. Obtain the mounting bracket and secure the drive(s) to the bracket. 2. Secure the drives to the chassis floor using four screws. 3. Connect drive cables. Screws Figure 3-8.
Chapter 3: Maintenance and Component Installation System Fans The 1019D-FHN13TP and 1019D-4C-FHN13TP systems come with four heavy-duty fans. There are additional sockets for two more optional fans to provide additional cooling, if needed, for a total of six fans. The 1019D-14CN-FHN13TP and 1019D-16C-FHN13TP systems come with six heavy-duty fans.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Installing the Air Shroud Air shrouds concentrate airflow to maximize fan efficiency. It does not require screws to install. Installing the Air Shroud 1. Position the air shroud in the chassis, as illustrated below. The air shroud fits just behind the fans.
Chapter 3: Maintenance and Component Installation Checking the Server Air Flow • Make sure there are no objects to obstruct airflow in and out of the server. • Do not operate the server without drives or drive carriers in the hot-swap drive bays. •...
This enables it to automatically sense and operate at a 100v to 240v input voltage. It will be necessary to shut down the system in order to change the power supply. If replacing, use the exact same model. New units can be ordered directly from Supermicro or authorized distributors.
Chapter 3: Maintenance and Component Installation PCI Expansion Cards The system includes a pre-installed riser card that positions one or two full-height, PCI-E x16 cards at a 90 degree angle, allowing it to fit inside the chassis. Installing PCI Expansion Cards 1.
Page 42
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual 3. Insert the expansion card into the riser card slot while aligning the card rear bracket with the chassis slot. R E V I S I DESCRIPTION 4. Secure the card bracket with screws. Screws Figure 3-13. Inserting the Expansion Card into the Riser Card Bracket ITEM Back Ground Color Text &...
Chapter 4: Motherboard Connections Chapter 4 Motherboard Connections This section describes the connections on the motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. A motherboard layout indicating component locations may be found in Chapter 1.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Power SMB (I C) Header The Power System Management Bus (I C) connector (JPI2C1) monitors the power supply. Refer to the table below for pin definitions. Power SMB Header Pin Definitions Pin# Definition Clock Data PMBUS_Alert Ground 4.2 Headers and Connectors Fan Headers...
Page 45
Chapter 4: Motherboard Connections SATA Ports T h e X11S D W - 4 C -T P13 F, X11S D W - 8 C -T P13 F, X11S D W -14 C N T-T P13 F, a n d X11SDW-16C-TP13F motherboards have four S-SATA 3.0 ports. Refer to the table below for pin definitions.
Page 46
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual VGA Header Connect a 16-pin VGA extension cable to JVGA1 for a VGA connecton. VGA Header Pin Definitions Pin# Definition Pin# Definition VGA_RED VGA_CRE VGA_BLE VGA_DET DDCSDA HSYNC VSYNC DDCSCL Intel RAID Key Header The JRK1 header allows the user to enable RAID functions. Refer to the table below for pin definitions.
Page 47
Chapter 4: Motherboard Connections General Purpose I/O Header The JGP1 (General Purpose Input/Output) header is a general purpose I/O expander on a pin header via the SMBus. Refer to the table below for pin definitions. GPIO Header Pin Definitions Pin# Definition Pin# Definition...
Page 48
Data Clock NVMe I C Header JNVI2C1 is a management header for the Supermicro AOC NVMe PCI-E peripheral cards. Connect a corresponding I C cable to this header. Refer to the table below for pin definitions. NVMe I C Header...
Page 49
Chapter 4: Motherboard Connections Nano SIM Slot The JSIM1 slot supports a Nano SIM card. LAN Port Activity LED JLANLED1 is the activity LED for LAN1, JLANLED2 is the activity LED for LAN2 - LAN5, and JLANLED3 is the activity LED for LAN6 - LAN9. JTGLED1, JTGLED2 JTGLED1 is the activity LED for LAN10 - LAN11, and JTGLED2 is the activity LED for LAN12 - LAN13.
JF1 contains header pins for various buttons and indicators that are normally located on a control panel at the front of the chassis. These connectors are designed specifically for use with Supermicro chassis. See the figure below for the descriptions of the front control panel buttons and LED indicators.
Page 51
Chapter 4: Motherboard Connections Overheat (OH)/Fan Fail Connect an LED cable to OH/Fan Fail connections on pins 7 and 8 of JF1 to provide warnings for chassis overheat and fan failure. Refer to the table below for pin definitions. OH/Fan Fail Indicator OH/Fan Fail LED Pin Definitions Pin Definitions (JF1)
Page 52
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Power Fail LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table below for pin definitions. Power Fail LED Pin Definitions (JF1) Pins Definition +3.3V Stby PWR LED Power LED The Power LED connection is located on pins 15 and 16 of JF1.
Chapter 4: Motherboard Connections 4.3 Rear I/O Ports The following rear input/output ports are provided by the motherboard. Figure 4-2. Rear I/O Ports Item Description Item Description Item Description Item Description COM1 SFP+ LAN13 LAN2 LAN9 USB5 (USB3.0) SFP+ LAN12 LAN5 LAN8 USB4 (USB3.0)
Page 54
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual COM Port/Header The motherboard has one COM port on the back panel I/O and one COM header on the motherboard to provide serial connections. COM Port Pin Definitions Pin# Definition Pin# Definition SP_DCDA SP_DSRA SP_RXDA SP_RTSA SP_TXDA SP_STSA SP_DTRA...
Page 55
Note: UID can also be triggered via IPMI on the motherboard. For more information on IPMI, please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com/ support/manuals/. UID LED...
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual 4.4 Jumpers Explanation of Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations.
Page 57
Chapter 4: Motherboard Connections SMBus to PCI-E Slots Jumpers JI2C1 and JI2C2 allow you to connect the System Management Bus (I2C) to the PCI-E slots. Both jumpers must be set to the same setting (JI2C1 controls the clock and JI2C2 controls the data). SMBus to PCI-E Slots Jumper Settings Jumper Setting...
Page 58
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Watch Dog Timer JWD1 controls the Watch Dog function. Watch Dog is a monitor that can reboot the system when a software application hangs. Jumping pins 1-2 will cause Watch Dog to reset the system if an application hangs. Jumping pins 2-3 will generate a non-maskable interrupt signal for the application that hangs.
Page 59
Chapter 4: Motherboard Connections USB Wake Up Use the JPUSB1 jumper to enable system wake up via a USB device. This jumper allows you to wake up the system by pressing a key on the USB keyboard or by clicking the USB mouse of your system.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual 4.5 LED Indicators LAN LEDs Thirteen LAN ports (LAN1 - LAN13) are located on the I/O back panel. Each LAN port has two LEDs. The yellow LED indicates activity, while the other Link LED may be green, amber, or off to indicate the speed of the connection.
The Supermicro website contains drivers and utilities for your system at https://www. supermicro.com/wftp. Some of these must be installed, such as the chipset driver. After accessing the website, go into the CDR_Images directory and locate the ISO file for your motherboard. Download this file to create a DVD of the drivers and utilities it contains.
Page 62
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Figure 5-1. Driver & Tool Installation Screen Note: Click the icons showing a hand writing on paper to view the readme files for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time.
5.2 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Chapter 6 UEFI BIOS 6.1 Introduction This chapter describes the AMI BIOS setup utility for the X11SDW-4C-TP13F, X11SDW-8C-TP13F, X11SDW-14CNT-TP13F, and X11SDW-16C-TP13F and provides the instructions on navigating the setup screens. The BIOS is stored in a Flash EEPROM and can be updated.
Chapter 6: UEFI BIOS 6.2 Main Setup When you first enter the AMI BIOS setup utility, you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS setup screen is shown below and the following features will be displayed: The Main tab page allows you to set the date and time, and it displays system information.
Page 66
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Supermicro X11SDW-4C-TP13F, X11SDW-8C-TP13F, X11SDW-14CNT-TP13F, or X11SDW-16C-TP13F BIOS Version This feature displays the version of the BIOS ROM used in the system. Build Date This feature displays the date when the version of the BIOS ROM used in the system was built.
Chapter 6: UEFI BIOS 6.3 Advanced Setup Configurations Use the arrow keys to select the Advanced tab and press <Enter> to access the submenu items. Caution: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency, or an incorrect DRAM timing setting may make the system unstable. If this occurs, revert to the manufacture default settings.
Page 68
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual INT19 Trap Response Interrupt 19 is the software interrupt that handles the boot disk function. When this feature is set to Immediate, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at bootup immediately and allow the drives that are attached to these host adaptors to function as bootable disks.
Page 69
Chapter 6: UEFI BIOS • Processor Max Ratio • Processor Min Ratio • Microcode Revision • L1 Cache RAM • L2 Cache RAM • L3 Cache RAM • Processor 0 Version Hyper-Threading (ALL) Select Enabled to support Intel Hyper-threading Technology to enhance CPU performance. The options are Disable and Enable.
Page 70
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Adjacent Cache Prefetch (Available when supported by the CPU) The CPU prefetches the cache line for 64 bytes if this feature is set to Disabled. The CPU prefetches both cache lines for 128 bytes as comprised if this feature is set to Enable. The options are Enable and Disable.
Page 71
Chapter 6: UEFI BIOS ENERGY_PERF_BIAS_CFG Mode The Energy Perfomance BIAS (EPB) feature allows you to configure CPU power and per- fomance settings. Select Maximum Performance to set the highest performance. Select Performance to optimize performance over energy efficiecy. Select Balanced Perfomance to priortize performance optimization while conserving energy.
Page 72
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Hardware PM State Control Hardware P-States This setting allows you to select between OS and hardware-controlled P-states. Select- ing Native Mode allows the OS to choose a P-state. Selecting Out of Band Mode allows the hardware to autonomously choose a P-state without OS guidance. Selecting Native Mode with No Legacy Support functions as Native Mode with no support for older hard- ware.
Page 73
Chapter 6: UEFI BIOS Chipset Configuration Warning: Setting the wrong values in the sections below may cause the system to malfunction. North Bridge Configuration Memory Configuration Enforce POR Select POR (Plan of Record) to enforce POR restrictions on DDR4 frequency and volt- age programming.
Page 74
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Mirror Mode This feature allows memory to be mirrored between two channels, providing 100% redundancy. The options are Disable and Enable Mirror Mode (1LM). Memory Rank Sparing Select Enable to enable memory-sparing support for memory ranks to improve memory performance.
Page 75
Chapter 6: UEFI BIOS Patrol Scrub Interval This feature allows you to decide how many hours the system should wait before the next complete patrol scrub is performed. Use the keyboard to enter a value from 0-24. The default setting is 24. IIO Configuration ...
Page 76
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual PCI-E Port Max Payload Size Use this feature to select the maximum payload size for this port. The options are 128B, 256B, and Auto. IOAT Configuration Disable TPH Transparent Huge Pages (TPH) is a Linux memory management system that enables communication in larger blocks (pages).
Page 77
Chapter 6: UEFI BIOS PassThrough DMA Use this feature to allow devices such as network cards to access the system memory without using a processor. Select Enable to use the Non-Isoch VT-d Engine Pass Through Direct Memory Access (DMA) support. The options are Enable and Disable. Use this feature to enable Non-Isoch VT-d Engine Address Translation Services (ATS) support.
Page 78
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Hot Plug Capable (Available when the device is detected by the system) Use this feature to enable hot plug support for PCIe root ports 1A~1D. The options are Disable and Enable. VMD Config for PStack1 Intel® VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack.
Page 79
Chapter 6: UEFI BIOS XHCI Hand-off This is a workaround solution for operating systems that do not support XHCI (Extensible Host Controller Interface) hand-off. The XHCI ownership change should be claimed by the XHCI driver. The settings are Enabled and Disabled. Port 60/64 Emulation Select Enabled for I/O port 60h/64h emulation support, which in turn will provide complete legacy USB keyboard support for the operating systems that do not support legacy USB...
Page 80
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Aggressive Link Power Management When this feature is set to Enable, the SATA AHCI controller manages the power usage of the SATA link. The controller will put the link in a low power mode during extended periods of I/O inactivity, and will return the link to an active state when I/O activity resumes.
Page 81
Chapter 6: UEFI BIOS SATA HDD Unlock This feature allows you to remove any password-protected SATA disk drives. The options are Disable and Enable. *If the feature "Configure sSATA as" above is set to RAID, the next two features will be available for configuration: sSATA RSTe Boot Info Select Enable to provide full int13h support for the devices attached to sSATA controller.
Page 82
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual PCIe/PCI/PnP Configuration The following information will display: • PCI Bus Driver Version • PCI Devices Common Settings: Above 4G Decoding (Available if the system supports 64-bit PCI decoding) Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address. The options are Disabled and Enabled.
Page 83
Chapter 6: UEFI BIOS Consistent Device Name Support Select enabled for the BIOS to consistently name network devices. The options are Disabled and Enabled. JMD2: M.2-H PCI-E 3.0 X2 lane 1 Type Use this feature to select the I/O type for this slot. The options are PCIE and USB 3.0. JMD1: M.2-H PCI-E 3.0 X4 OPROM Use this feature to select which firmware type to be loaded for the add-on card in this slot.
Page 84
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Network Stack Configuration Network Stack Select Enabled to enable PXE (Preboot Execution Environment) or UEFI (Unified Extensible Firmware Interface) for network stack support. The options are Enabled and Disabled. *If the feature above is set to Enabled, the next six features will be available for configuration: Ipv4 PXE Support Select Enabled to enable IPv4 PXE boot support.
Page 85
Chapter 6: UEFI BIOS Change Settings This feature specifies the base I/O port address and the Interrupt Request address of Serial Port 1. Select Auto for the BIOS to automatically assign the base I/O and IRQ address to a serial port specified. The options are Auto, (IO=3F8h; IRQ=4), (IO=2F8h; IRQ=4), (IO=3E8h;...
Page 86
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Console Redirection Settings Terminal Type This feature allows you to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support. Select ANSI to use the Extended ASCII Character Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes.
Page 87
Chapter 6: UEFI BIOS Resolution 100x31 Select Enabled for extended-terminal resolution support. The options are Disabled and Enabled. Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support. The options are 80x24 and 80x25. Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator designed for the Windows OS.
Page 88
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Bits per second Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines.
Page 89
Chapter 6: UEFI BIOS Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SCO, ESCN, and VT400. Redirection After BIOS POST Use this feature to enable or disable legacy console redirection after BIOS POST.
Page 90
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Terminal Type Use this feature to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII character set. Select VT100+ to add color and function key support. Select ANSI to use the extended ASCII character set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes.
Page 91
Chapter 6: UEFI BIOS High Precision Event Timer Select Enabled to activate the High Precision Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback and reducing the dependency on other timestamp calculation devices, such as an x86 RDTSC Instruction embedded in the CPU.
Page 92
Use this feature to disable or enable Platform Hiearchy (PH) Randomization. The options are Disabled and Enabled. SMCI BIOS-Based TPM Provision Support Use feature to enable the Supermicro TPM Provision support. The options are Disabled and Enabled. TXT Support Intel TXT (Trusted Execution Technology) helps protect against software-based attacks and ensures protection, confidentiality and integrity of data stored or created on the system.
Page 93
Chapter 6: UEFI BIOS Intel(R) Virtual RAID on CPU Intel(R) VROC with VMD Technology 5.4.0.1039 RAID volume and Intel VMD Controller information will be displayed if they are detected by the system. Driver Health This submenu displays the health status of the drivers and controllers below. Intel®...
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual 6.4 Event Logs Use this tab page to configure Event Log settings. Change SMBIOS Event Log Settings Enabling/Disabling Options SMBIOS Event Log Change this feature to enable or disable all features of the SMBIOS Event Logging during system boot.
Page 95
Chapter 6: UEFI BIOS SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events. The options are Enabled and Disabled. MECI (Multiple Event Count Increment) Enter the increment value for the multiple event counter. Enter a number between 1 to 255. The default setting is 1.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual 6.5 IPMI Use this tab page to configure Intelligent Platform Management Interface (IPMI) settings. BMC Firmware Revision This feature displays the IPMI firmware revision used in your system. IPMI STATUS This feature displays the status of the IPMI firmware installed in your system. System Event Log Enabling/Disabling Options SEL Components...
Page 97
Chapter 6: UEFI BIOS When SEL is Full This feature allows you to determine what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full.
Page 98
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Station MAC Address This feature displays the Station MAC address for this computer. Mac addresses are 6 two-digit hexadecimal numbers. Gateway IP Address This feature displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i.e., 192.168.10.253).
Page 99
IPMI features. The Disable option is for applications that require faster power on time without using Supermicro Update Manager (SUM) or extended IPMI features. The BMC network configuration in the BIOS setup will also be invalid when IPMI Extended Instruction is disabled.
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual 6.6 Security Use this tab page to configure Security settings. Administrator Password Use this feature to set the administrator password which is required to enter the BIOS setup utility. The length of the password should be from 3 to 20 characters long. Password Check Select Setup for the system to check for a password at Setup.
Page 101
Chapter 6: UEFI BIOS Secure Boot Mode This feature allows you to select the desired secure boot mode for the system. The options are Standard and Custom. *If Secure Boot Mode is set to Custom, Key Management features are available for configuration: CSM Support This feature is for manufacturing debugging purposes.
Page 102
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Key Exchange Keys (KEK) Update Select Yes to load a factory default KEK or No to load from a file on an external media. Append Select Yes to add the KEK from the manufacturer's defaults list to the existing KEK. Select No to load the KEK from a file.
Chapter 6: UEFI BIOS 6.7 Boot Use this tab page to configure Boot Settings. Boot mode select Use this feature to select the boot mode. The options are LEGACY, UEFI, and DUAL. LEGACY to EFI Support Select Enabled to boot EFI OS support after Legacy boot order has failed. The options are Disabled and Enabled.
Chapter 6: UEFI BIOS 6.8 Save & Exit Use this tab page to configure Save & Exit settings. Save Options Discard Changes and Exit Select this feature to quit the BIOS Setup without making any permanent changes to the system configuration and reboot the computer. Select Discard Changes and Exit from the Save &...
Page 106
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Default Options Restore Defaults To set this feature, select Restore Defaults from the Save & Exit menu and press <Enter>. These are factory settings designed for maximum system stability, but not for maximum performance. Save As User Defaults To set this feature, select Save as User Defaults from the Save &...
Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
Page 108
Appendix A: Standardized Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
Page 109
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual . ٌ ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز ٍ...
Page 110
Appendix A: Standardized Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .יש...
Page 111
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
Page 112
Appendix A: Standardized Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告...
Page 113
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد انطاقت قبم انىصىل إىن امنناطق انداخهيت نههيكم نتثبيج أو إ ز انت مكىناث الجهاز 경고! 시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원 공급장치로부터...
Page 114
Appendix A: Standardized Warning Statements Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !אזהרה .צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד واملدربيه...
Page 115
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
Page 116
Appendix A: Standardized Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
Page 117
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل اسحبذال البطارية فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة 경고! 배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일하거나 제 조사에서...
Page 118
Appendix A: Standardized Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
Page 119
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
Page 120
Appendix A: Standardized Warning Statements هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
Page 121
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual תיאום חוקי החשמל הארצי !אזהרה .התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة بالكهرباء 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
Page 122
Appendix A: Standardized Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. סילוק המוצר !אזהרה .סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה التخلص...
Page 123
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
Page 124
Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
Page 126
사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
Appendix C: System Specifications Appendix C System Specifications Processors Single Intel Xeon D-2146NT with TDP 80W for 1019D-FHN13TP in a FCBGA2518 socket Single Intel Xeon D-2123IT with TDP 60W for 1019D-4C-FHN13TP in a FCBGA2518 socket Single Intel Xeon D-2177NT with TDP 105W for 1019D-14CN-FHN13TP in a FCBGA2518 socket Single Intel Xeon D-2183IT with TDP 100W for 1019D-16C-FHN13TP in a FCBGA2518 socket Note: Refer to the motherboard specifications pages on our website for updates to supported processors.
Page 128
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual Chassis SC513BTS-350WB for 1019D-FHN13TP and 1019D-4C-FHN13TP SC513BTS-505WB for 1019D-14CN-FHN13TP and 1019D-16C-FHN13TP 1U rackmount; (WxHxD) 17.2 x 1.7 x 15 in. (437 x 43 x 381mm) System Cooling 1019D-FHN13TP and 1019D-4C-FHN13TP: Four 40mm PWM fans, plus an option for two more fans 1019D-14CN-FHN13TP and 1019D-16C-FHN13TP: Six 40mm PWM fans Power Supply 1019D-FHN13TP and 1019D-4C-FHN13TP...
Page 129
Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
Page 130
Directory of a USB device or a writeable CD/DVD. Note: If you cannot locate the "Super.ROM" file in your driver disk, visit our website at www.supermicro.com to download the BIOS image into a USB flash device and rename it "Super.ROM" for BIOS recovery use.
Page 131
Appendix B: UEFI BIOS Recovery 4. After locating the new BIOS binary image, the system will enter the BIOS Recovery menu as shown below. Note: At this point, you may decide if you want to start with BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below.
Page 132
SuperServer 1019-(4C/14CN/16C-)FHN13TP User's Manual 6. After the process of BIOS recovery is completed, press any key to reboot the system. 7. Using a different system, extract the BIOS package into a bootable USB flash drive. 8. When a DOS prompt appears, enter FLASH.BAT BIOSname.### at the prompt. Note: Do not interrupt this process until BIOS flashing is completed.
Need help?
Do you have a question about the SuperServe 1019D-FHN13TP and is the answer not in the manual?
Questions and answers