Start-up
6.2

Installation

To install the floor heating actuator, please proceed as
follows:
Open the cover (D). Therefore, release the catch
under the slot for opening (C) by pushing it with
a screwdriver. Remove the cover by pulling it up-
wards (see fig. 5).
Connect the neutral conductor to connecting
terminal N (G) .
Press the terminal down using an appropriate
screw driver to open the connecting terminal.
Thread the corresponding cable. Release the ter-
minal to close it and to fix the cable (see fig. 6).
Connect the phase conductor to connecting ter-
minal L (G) .
Plug in the connecting cable of the valve actu-
ators in your heating circuits to the connecting
terminals (H-I). Connect a heating pump using
connecting terminal (H).
Make sure that all connecting cables are fixed
properly to the cable bushings before closing the
cover.
Close the cover again. Therefore, push the latches
of the cover into the openings provided and press
it down.