HomeMatic HmIP-FAL230-C6 Installation Instructions And Operating Manual page 55

Floor heating actuator – 6 channels, 230 v
Hide thumbs Also See for HmIP-FAL230-C6:
Table of Contents

Advertisement

Available languages

Available languages

voltage sub-distribution board), DIN 18015-x. In
this case, the installation must be made on a
mounting rail (DIN rail) according to EN50022.
Installation and wiring have to be performed
according to VDE 0100 (VDE 0100-410, VDE
0100-510 etc.). Please consider the technical
connection requirements (TAB) of your energy
supplier.
Please observe the hazard information in section
„2 Hazard information" on page 47 during in-
stallation.
Permitted cable cross sections for the cable bushings of
the floor heating actuator are:
Cable bushings
1 (J) (see fig. 2)
2 (K) (see fig. 2)
3 (L) (see fig. 2)
Permitted cable cross sections for connecting to the
connecting terminals of the floor heating actuator:
rigid cable [mm
0.75 – 1.50
Cable cross section [mm
> 5.2
> 8.2
> 3.2
2
]
flexible cable with/
without ferrule [mm
0.75 – 1.50
Start-up
2
]
2
]
55