1.5 Alarm Setup
1. Connect alarm input device to the alarm input of I/O cable.
2. Connect alarm output device to the alarm output of I/O cable.
3. Open the WEB, set alarm input and output. Alarm input on WEB corresponds to I/O cable on device. When there
is an alarm, the input device will generate a signal of high and low level. Set corresponding NO and NC inputs.
4. Set the WEB alarm output.
Mode A: Level application
Port
1
2
3
4
5
8
Crucial evidence. Always.
Name
ALARM_NO
ALARM_COM
ALARM_IN1
ALARM_IN2
GND
Mode B: Switch application
Function
Alarm output port
NO: Normal open alarm output port
Must be used with ALARM_COM
Alarm output public port
Alarm input port 1
Alarm input port 2
Ground port