INSTALLATION REQUIREMENTS
ELECTRICAL
A properly‐grounded horizontally‐ mounted
electrical receptacle should be installed no higher
than 3" (7.6 cm) above the floor, no less than 2"
(5 cm) and no more than 8" (20,3 cm) from the
left side (facing product).
Check all local code requirements.
GAS
An agency‐approved, properly‐sized manual shut‐
off valve should be installed no higher than 3"
(7.6 cm) above the floor and no less than 2" (5
cm) and no more than 8" (20.3 cm) from the right
side (facing product).
To connect gas between shut‐off valve and
regulator, use agency‐approved, properly sized
flexible or rigid pipe. Check all local code
requirements.
INSTALLATION ADJACENT TO KITCHEN
This range may be installed directly adjacent to
existing countertop high cabinets (36" or 91.5 cm
from the floor).
For the best look, the worktop should be level
with the cabinet countertop. This can be
accomplished by raising the unit using the
adjustment spindles on the legs.
ATTENTION: the range CANNOT be installed
directly adjacent to kitchen walls, tall cabinets,
tall appliances, or other vertical surfaces above
36" (91.4 cm) high. The minimum side clearance
in such cases is 6" (15.2 cm).
Wall cabinets with minimum side clearance must
be installed 18" (45.7 cm) above the countertop
with countertop height between 35 ½" (90.2 cm)
and 37 ¼" (94.6 cm). The maximum depth of wall
cabinets above the range shall be 13" (33.0 cm)
A
48" (122 cm)
B
36" (91,5 cm)
C
13" (33,0 cm)
D
18" (45,7 cm)
E
35"1/2(90,2 cm) /
F
6" (15,2 cm)
12
CABINETS
37" ¼ (94,6 cm)