EXHAUST HOOD INSTALLATION
This range will best perform when used with PRO
line Bertazzoni exhaust hoods. These hoods have
been designed to work in conjunction with the
Bertazzoni range and have the same finish for a
perfect look.
For maximum performance, the height of the
bottom of the hood from the worktop should be
between 25 1/2" (65 cm) and 31 1/2" (80 cm).
This would typically result in the bottom of the
hood being 61 1/2" (156.2 cm) to 67 1/2" (171.5
cm) above the floor. These measurements
provide for safe and efficient operation of the
hood.
Before installation of the exhaust hood, consult
local or regional building and installation codes
for additional specific clearance requirements.
Refer to the range hood installation instructions
provided by the manufacturer for additional
information.
ELECTRICAL CONNECTION
This unit is manufactured for a polarized,
grounded 120 volt/60 Hz, 16 amp system.
Electric power consumption is about 1200 W.
The minimum of 102 VAC is required for proper
operation of gas ignition systems.
The circuit must be grounded and properly
polarized.
The unit is equipped witth a SJT power cord. In
case of replacement, the power cord shall be
replaced with one of the same type, size and
length.
This appliance is equipped with a three‐prong
plug for your protection against shock hazard and
should be plugged directly into a properly
grounded socket. Do not cut or remove the
grounding prong from this plug.
13
ELECTRICAL GROUNDING