Electrical Requirements
3-wire connection : Direct wire
Caution!
Grounding through the neutral conductor is
prohibited for
1. New branch-circuit
installations
2. Mobile homes.
3. Recreational
vehicles.
4. Areas where local
codes prohibit
grounding through the neutral conductor.
Prepare minimum 5 ft. (1.52 m) of length in
order for dryer to be replaced.
First, strip 3 1/2" (8.9 cm) of outer sheath
from end and strip 1" of insulation from each
conductor.
Then, put the hooked shape end of the
wire under the screw of the terminal block
(hooked end facing rightward) and pinch
the hook together and tighten the screw
securely.
1. Connect the neutral wire (white) of
power cord to the center terminal block
screw.
2. Connect the red and black wires to the
left and right terminal block screws.
3. Make sure that the strain relief screw is
tightened.
Be sure that all terminal block nuts are on
tight and power cord is in right position.