4-Wire Connection: Direct Wire - Asko TL751 XXL Operating Instructions Manual

Asko tl751xxl:
Hide thumbs Also See for TL751 XXL:
Table of Contents

Advertisement

Electrical requirements

4-wire connection: Direct wire

Caution!
Grounding through the
neutral conductor is
prohibited for
1.
New branch-circuit
installations.
2.
Mobile homes.
3.
Recreational vehicles
4.
Areas where local codes prohibit
grounding through the neutral
conductor.
Prepare minimum 5 ft. (1.52 m) of length in
order for dryer to be replaced.
First, peel 5" (12.7 cm) of covering material
from end. Strip 5 inches of ground wire
insulation. After cutting 1 1/2" (3.8 cm) from
3 other wires peel insulation back 1" (2.5
cm). Make ends of 3 wires a hook shape.
36
3-wire receptacle
(NEMA type10-30R)
Then, put the hooked shape end of the
wire under the screw of the terminal block
(hooked end facing rightward) and pinch
the hook together and tighten the screw
securely.
1.
Connect neutral wire (white) of power
4-wire direct
cord to center terminal block screw.
2.
Connect red and black wires to the left
and right terminal block screws.
3.
Make sure that the strain relief screw is
tightened.
Be sure that all terminal block nuts are on
tight and power cord is in right position.
3-wire direct
Customer Care Center
1-800-898-1879
www.askousa.com

Advertisement