Battery Connection - MotorGuide X3-40 Operation And Maintenance Manual

Table of Contents

Advertisement

WIRING AND BATTERY INFORMATION

Battery Connection

Before working around electrical system components, disconnect the battery
cables from the battery to prevent injury or damage to the electrical system
due to an accidental short circuit.
Disconnecting or connecting the battery cables in the incorrect order can
cause injury from electrical shock or can damage the electrical system.
Always disconnect the negative (‑) battery cable first and connect it last.
Failure to operate the trolling motor within the recommended voltage
specifications can cause product damage. Do not exceed the maximum
supply voltage.
IMPORTANT: Refer to the decal on the head of the trolling motor to determine
the voltage requirements of your trolling motor.
12-VOLT BATTERY CONNECTION
1. Starting with the negative (–) lead, disconnect the battery cables from the
engine starting or accessory battery.
2. Install a 50‑amp (good) or 60‑amp (best) manual reset circuit breaker in
line with the trolling motor power cable positive (+) lead and the trolling
motor battery positive (+) terminal.
3. Connect the positive (+) trolling motor lead to the positive (+) trolling
motor battery terminal.
4. Connect the negative (–) trolling motor lead to the negative (–) trolling
motor battery terminal.
5. Connect a common ground bond from the trolling motor battery negative
(–) terminal to the engine starting battery negative (–) terminal.