WIRING AND BATTERY INFORMATION
6. Starting with the positive (+) lead, reconnect the battery cables to the
engine starting or accessory battery.
a
b
a -
Power cables to trolling motor
b -
Manual reset circuit breaker
c -
Trolling motor battery
d -
Engine starting or accessory battery
e -
Power cables to engine
f -
Common ground bond
24-VOLT BATTERY CONNECTION
1. Starting with the negative (–) lead, disconnect the battery cables from the
engine starting or accessory battery.
2. Install a 50‑amp (good) or 60‑amp (best) manual reset circuit breaker in
line with the trolling motor power cable positive (+) lead and the trolling
motor battery B positive (+) terminal.
3. Connect the positive (+) trolling motor lead to the positive (+) terminal on
trolling motor battery B.
4. Connect a jumper wire (reference gray) between the negative (–) terminal
on battery B to the positive (+) terminal on battery A.
IMPORTANT: The jumper wire should be the same wire gauge as the
negative (–) and positive (+) power cables.
5. Connect the trolling motor negative (–) lead to the negative (–) terminal on
battery A.
c
f
e
d
45086