Server
1
Press
and authenticate with the Admin level credential.
2
Select NETWORK > Server.
3
Change the desired item.
•
Device -> Server: You can send a connection signal from the device to a server with the input information directly. When you
select Server -> Device, Server IP, Server URL and Server Port cannot be entered.
Server IP: Enter the IP address of the PC on which BioStar 2 is installed. Input is accepted only when Device -> Server is set for
•
Connection Mode.
•
Server URL: Enter server URL instead of Server IP. Input is accepted only when Device -> Server is set for Connection Mode.
Server Port: Enter the port of the PC on which BioStar 2 is installed. Input is accepted only when Device -> Server is set for
•
Connection Mode.
4
To save settings, press OK.
Serial Setting
1
Press
and authenticate with the Admin level credential.
2
Select NETWORK.
3
Change the desired item.
RS-485: Select the RS-485 mode.
•
Baud Rate: Select the desired baud rate.
•
4
To save settings, press OK.