3.1
Single Speed Wiring (for QC CL-1500)
1. For this installation, you will need (2) 2 wire Romex, and an 8 Hour Timer. Using the included wire nuts,
tie the black wire from the first 2 wire Romex from the power source to the black wire on the timer.
(see Figure 3.1A)
2. Using a wire nut, tie the black wire on the 2 wire Romex from the fan to the red wire on the timer.
3. Using a wire nut, tie the bare copper wires together with the green ground wire on the timer.
4. Using a wire nut, tie the white neutral wires from the Romex to the white neutral wire on the timer.
5. Begin wiring the fan by opening up the handy box. Take off the wire nuts within the handy box.
Unscrew the green ground wire. Detach the green ground wire from the power cord. Remove the
power cord. Re-attach the ground screw and wire to the handy box. Cut your green ground wire in half
and strip both sides. (see Figure 3.1B)
Figure 3.1A
1-888-QUIETCOOL
Power Source
Power Source
Tie White Common
Tie White Common
Wires Together
Wires Together
Tie Ground & Bare
Tie Ground & Bare
Copper Wires Together
Copper Wires Together
Black Tied
Black Tied
Together with Black
Together with Black
8 HOUR
8 HOUR
4 HOUR
4 HOUR
2 HOUR
2 HOUR
1 HOUR
1 HOUR
HOLD
HOLD
Red Switch Leg
Red Switch Leg
Whole House Fan
Whole House Fan

Single Speed Wiring

Single Speed Wiring