  • Page 1 OWNER’S GUIDE SMART ATTIC ROOF MOUNT FAN AFR SMT ES-2.0 DO NOT THROW AWAY! SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER’S GUIDE. LEAVE WITH HOMEOWNER...
  • Page 2: Table Of Contents

    3. WIRING ..........7 3.1 Three Speed Wiring - AFR SMT ES-2.0 ....7 3.3 Smart Control Hub - LED Indicators .
  • Page 3: System Overview

    CONGRATULATIONS on the purchase of your new QuietCool Smart Attic Fan! QuietCool Attic Fans are the best in the business. New for 2020, our Smart Line of attic fans have gotten even smarter! Now through the use of a smartphone app, you can control all the settings of your...
  • Page 4: System Venting Requirements

    Venting plays a very significant role in the performace of QuietCool fans. QuietCool recommends a mini- mum of 1 SQ. FT. of venting for every 750 CFM in the QuietCool system. If an attic has at least 1:750 attic venting, the QuietCool system will operate efficiently and effectively. If an attic has less than 1:750 attic venting, the system may not operate as efficiently, or effectively, as it could with 1:750 attic venting.
  • Page 5: Getting Started - Important

    4. FOLLOW INSTRUCTIONS - All installation and operating instructions should be followed. 5. WATER - The QuietCool system should not be used near water. If you live in a very humid climate, be sure to cover your damper box with insulation to reduce condensation.
  • Page 6: Installation

    1. Determine in which area you would like to install your Figure 2.1A QuietCool AFR. 2. From inside the attic, find the center point between the two roof rafters and mark it as the center of the fan hole. Partially insert a screw into the center point mark.
  • Page 7 Figure 2.1F 10. Apply weatherproof sealant all around the fan housing and secondary flashing, closing the gap between the flashing, the fan unit, and the tile. Using an angle grinder, cut the removed tiles as needed. Re-install the tile around the fan unit. 11.
  • Page 8: Wiring

    If you would like to hard-wire the fan, or it is required by your local building codes, please follow the wiring instructions below. THREE SPEED WIRING - (AFR SMT ES-2.0) 1. Using a wire nut, connect the black wire from the power cord and the black wire from the fan to the black wire from the Hub.
  • Page 9: Smart Control Hub - Led Indicators

    Figure 3.1A Attach green ground wires to ground screw Set dip switches: 1 - OFF Hub Wiring Legend 2 - OFF Hot Wire 3 - ON Neutral Wire High Speed Wire Medium Speed Wire Low Speed Wire Speed Bluetooth POWER Temp and Hum Test Pair...
  • Page 10: System Operating Instructions

    4. SYSTEM OPERATING INSTRUCTIONS DOWNLOADING THE QUIETCOOL SMART CONTROL APP Download the QuietCool Smart Control App onto your iOS or Android device. Scan the QR code above or visit QuietCoolSystems.com/smart-control/ and click the link to download the app to your device.
  • Page 11 FAN CONTROL PAGE This page is accessed when you tap on your fan from the Home Page. On this page you can see the current conditions in your attic, activate the different modes of the fan, and get to the Fan Settings page. FAN SETTINGS PAGE This page is used to adjust the settings of the fan.
  • Page 12 Make sure that this number matches the specification of the fan you purchased. We are setting up an AFR SMT ES-2.0 which is a 3-speed fan. The QuietCool Smart Attic Fan Control has an innovative Smart mode that allows the fan to adjust the speed based on the temperature and humidity conditions in your attic.
  • Page 13 TEMPERATURE The settings you choose in this section will • change what temperature the fan will come on at each set speed. Tap on any speed to adjust the temperature for • each speed. HUMIDITY Turn Fan Off: This is the humidity percentage •...
  • Page 14 Timer Mode. Once activated, you can select your speed by tapping Set Speed. You can also select your runtime by tapping Set Time. When Timer Mode is active, you will see your remaining time left on the timer at the top of the screen. 1-888-QUIETCOOL...
  • Page 15 SMART MODE Smart Mode will automatically change the speed based on the attic temperature and humidity. To activate Smart Mode, simply tap Activate Smart Mode. In Smart Mode, the first paramater that is checked is the Turn Fan Off humidity level. Regardless of the temperature in the attic, if the Humidity level in the attic is above the Turn Fan Off humidity setting, the fan will not turn on, or...
  • Page 16 Pair Mode. Tap OK. Now, on the device you are trying to pair, open up the Smart Control app and tap the fan. You will now be taken to the Fan Setup page and you are now paired. 1-888-QUIETCOOL...
  • Page 17 FIRMWARE UPDATE Your attic fan includes a Firmware Update feature in order for us to update your Fan Hub to include bug fixes and additional features in the future. We recommend checking for a new firmware update a few times per year. To check for an available firmware update, go into the Fan Settings page and tap Firmware Update.
  • Page 18: Frequently Asked Questions

    This control features an innovative fire safety shut-off that will automatically turn the fan off if it detects a temperature above 182ºF in your attic. The purpose of this is to shut off in the event of a house fire to prevent the spread of flames. 1-888-QUIETCOOL...
  • Page 19 QUIETCOOLSYSTEMS.COM...
  • Page 20 1-888-QUIETCOOL...
  • Page 21 QUIETCOOLSYSTEMS.COM...
  • Page 22 No subsequent purchaser of the unit or of a home in which it is installed is entitled to any of the benefits of this warranty. The QuietCool Product that you have purchased has a limited warranty from the date of purchase against defects in workmanship and materials.
  • Page 23: Warranty

    The electrical motor is to be used solely as a direct replacement for a motor of the same model in QC Manufacturing, Inc., QuietCool products. Using the motor in any other product could result in electrical shock and/ or fire, which may cause property damage, serious injury or even death. Any motor replacement should be installed by a qualified licensed electrician in accordance with local, state and national electrical codes and standards.
  • Page 24 Rev. 9/26/22 FAN SERIAL NUMBER INFORMATION RETAIN FOR YOUR RECORDS. SERIAL NUMBER IS REQUIRED FOR WARRANTY PURPOSES. 1-888-QUIETCOOL | WWW.QUIETCOOLSYSTEMS.COM...