Download Print this page

Physical Installation - Emerson Rosemount ET410 Quick Start Manual

Power module for wireless corrosion transmitter
Hide thumbs Also See for Rosemount ET410:

Advertisement

Quick Start Guide
2

Physical installation

2.1
Compatibility
Permasense WT100 Corrosion Transmitter
Rosemount Wireless Permasense WT210 Corrosion Transmitter
Rosemount Wireless Permasense ET210 Corrosion Transmitter
Rosemount Wireless Permasense ET310 Corrosion Transmitter
Rosemount Wireless Permasense ET410 Corrosion Transmitter
2.2
Required tooling
Tooling is supplied in the Permasense IK220 Installation Kit:
Hex key, 2.5 mm, for power module retaining bolts
2.3
Power module installation
To install the power module:
1. Check power module and sensor terminals are clean and corrosion
free.
2. Ensure the ring seal around the connector on the power module is
present.
3. Clip on the power module as shown in
4. Fit the two M3 retaining bolts using a 2.5 mm AF hex key.
5. The sensor will resume normal operation. No configuration is
required.
Figure 2-1: Rosemount BP20E Installation
6
December 2020
Figure
2-1.
Emerson.com/Rosemount

Advertisement

loading