Mounting Instruction
Industrial Ethernet Workgroup Switch
MACH104 Full Gigabit Family
MACH104-20TX-F
FAULT
USB
V.24
FAULT
RM
Sb
P
MACH104-20TX-F...
MACH104-20TX-FR
FAULT
USB
V.24
FAULT
RM
Sb
P
MACH104-20TX-FR...
MACH104-20TX-F-4PoE
FAULT
USB
V.24
FAULT
RM
Sb
P
MACH104-20TX-F-4PoE...
Mounting Instruction MACH104
Release 07 07/2014
5
7
1
3
2
4
6
8
5
7
1
3
2
4
6
8
P
5
7
1
3
2
4
6
8
9
11
13
15
10
12
14
16
9
11
13
15
10
12
14
16
9
11
13
15
10
12
14
16
https://hirschmann-support.belden.eu.com
17
19
21
23
18
20
22
24
17
19
21
23
18
20
22
24
17
19
21
23
18
20
22
24
Technical support

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hirschmann MACH104 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Belden Hirschmann MACH104 Series

  • Page 1 Mounting Instruction Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family MACH104-20TX-F FAULT V.24 FAULT MACH104-20TX-F... MACH104-20TX-FR FAULT V.24 FAULT MACH104-20TX-FR... MACH104-20TX-F-4PoE FAULT V.24 FAULT MACH104-20TX-F-4PoE... Mounting Instruction MACH104 Technical support Release 07 07/2014 https://hirschmann-support.belden.eu.com...
  • Page 2 The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone. ©...
  • Page 3: Table Of Contents

    Contents Safety instructions About this manual Legend Description Display elements 1.1.1 Device state 1.1.2 Port state Management interfaces 1.2.1 USB interface Installation Wiring and assembling the signal contact Installing the device and grounding 2.2.1 Selecting the assembly location 2.2.2 Mounting on a flat surface 2.2.3 Mounting in a switch cabinet 2.2.4 Mounting on the wall 2.2.5 Grounding the device...
  • Page 4: Safety Instructions

    Safety instructions General safety instructions  You operate this device with electricity. The proper and safe operation of this device depends on proper handling during transportation, proper storage and assembly, and conscientious operation and maintenance procedures. Improper use of this device is associated with the risk of personal injury or property damage.
  • Page 5 National and international safety regulations   Verify that the electrical installation meets local or nationally applicable safety regulations. Grounding the device  The device is grounded via the operating voltage connections. Working voltage  The operating voltage is electrically isolated from the housing. ...
  • Page 6 2011/65/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 2004/108/EC (EMC) Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compati- bility.
  • Page 7 Appropriate testing has established that this device fulfills the require- ments of a class A digital device in line with part 15 of the FCC regula- tions. These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment. The device creates and uses high frequencies and can also radiate high frequencies, and if it is not installed and used in accordance with this operating manual, it can cause radio transmission interference.
  • Page 8: About This Manual

    About this manual The “Mounting Instructions” document contains safety instructions and infor- mation that you require to mount the device. The following manuals are available as PDF files on the CD/DVD supplied:  Installation user manual with additional information on the device: –...
  • Page 9: Description

    Description Display elements After the working voltage is set up, the software starts and initializes itself. Afterwards, the device performs a self-test. During this process, various LEDs light up. The process takes around 15 seconds. 9 11 13 15 17 19 21 23 MACH104-20TX-F FAULT...
  • Page 10: Port State

    Display Color Activity Meaning Working Green Lights up Operating voltage is on voltage None Operating voltage is too low 1.1.2 Port state These LEDs display port-related information. Display Color Activity Meaning Link status None Device detects an invalid or missing link Green Lights up Device detects a valid link...
  • Page 11: Installation

    Installation Note: Read the safety guidelines under “Safety instructions” on page Wiring and assembling the signal contact FAULT Figure 2: 2-pin terminal block WARNING ELECTRIC SHOCK Never insert sharp objects (small screwdrivers, wires, etc.) into the connec- tion terminals for the signal lines, and do not touch the terminals! Non-adherence to these instructions can lead to death, serious physical injury or material damage.
  • Page 12: Installing The Device And Grounding

    Installing the device and grounding The device can be mounted on a flat surface, in a 19" standard switch cabinet, or on the wall. 2.2.1 Selecting the assembly location Select the assembly location according to the safety guidelines (see on page 4 “Safety instructions”).
  • Page 13: Mounting On The Wall

    MACH104-20TX-F FAULT V.24 FAULT Figure 3: Mounting the MACH104 in the 19" cabinet  Fasten the device by screwing the brackets to the switch cabinet. Note: When operating the device in an environment with strong vibrations, you have the option to additionally fasten the back of the device to the switch cabinet using two brackets.
  • Page 14: Operating The Device

    Operating the device WARNING ELECTRIC SHOCK Connect solely an working voltage that corresponds to the type plate of your device. Failure to follow these instructions can result in death, serious injury, or equipment damage. Note: Read the safety guidelines under “Working voltage”...
  • Page 15: Deinstallation

    Deinstallation Removing the device  Disconnect the data cables.  Disable the working voltage.  Disconnect the operating voltage.  Remove the power connector from the device.  To detach the device from the switch cabinet or the wall, remove the screws from the brackets on the device.
  • Page 16: Technical Data

    Technical data General technical data  Dimensions See “Dimension drawings” on page 17. Weight MACH104-20TX-F... 4.2 kg MACH104-20TX-FR... 4.4 kg MACH104-20TX-F-4PoE... 4.6 kg Operating voltage Rated voltage range AC 100 V ... 240 V, 50 Hz ... 60 Hz Voltage range AC incl. 90 V AC - 265 V AC, 47 Hz - 63 Hz maximum tolerances Current consump-...
  • Page 17 Dimension drawings  462,6 0.13 18.21 0.13 inch 19,3 19,3 0.76 17.48 0.76 Power consumption/power output  MACH104device Maximum Maximum power consumption power output MACH104-20TX-F... 35 W 119 Btu (IT)/h MACH104-20TX-FR... 35 W 119 Btu (IT)/h MACH104-20TX-F-4PoE..., when 4 x 110 W 170 Btu (IT)/h Class 0 Powered Device connected...
  • Page 18 Number Article 1 × Non-heating appliance cable (Euro model) 1 × Mounting instruction 1 × CD/DVD with manual Underlying technical standards  The device generally fulfills the norms and standards named in their current versions. The device has an approval based on a specific standard or de facto stan- dard solely if the approval indicator appears on the housing.
  • Page 19 Mounting Instruction MACH104 Release 07 07/2014...

Table of Contents