Mice switch power, mice switch media modules (114 pages)
Summary of Contents for Belden Hirschmann MAMMUTHUS MTS2600
Page 1
User manual Installation MAMMUTHUS ACCESS LAYER & DISTRIBUTION LAYER SWITCH – MTS2600/2700/2800 MAMMUTHUS POWER MODULE – MTM2700-PSU500/PSU120 MAMMUTHUS MEDIA MODULE – MTM2700-2X Installing MAMMUTHUS SWITCH Technical support Published on 01/2020 http:// hirschmann-it.support.belden.com...
Page 2
The performance characteristics described herein shall be binding only upon the express consent of the parties at the time of signing the contract. This paper is produced by Belden within its capacity. Belden reserves the right to change the contents of this manual without prior notice. Belden does not guarantee the correctness or accuracy of the information in this manual.
Contents Safety guidelines About the manual Legend 1 Description 1.1 General equipment description 1.2 Equipment name and product code 1.2.1 Basic device 1.2.2 Power module 1.2.3 Media module 1.3 Equipment view 1.3.1 MTS2624-4X-B 1.3.2 MTS2724-4X-FP-S 1.3.3 MTS2724-6X-MP-E 1.3.4 MTS2748-6X-MP-E 1.3.5 MTS2824-4X-S 1.3.6 MTS2824-6X-E 1.3.7 MTS2824F-4X-S 1.3.8 MTS2832TF-4X-E...
Page 4
1.5.4 PoE(+) support 1.5.5 Out-of-band management port 1.6 Display unit 1.6.1 Equipment status 1.6.2 Port Status 1.7 Management interface 1.7.1 DC0 interface (external management) 1.7.2 USB interface 2 Installation 2.1 Unpack the box for inspection 2.2 Install power module (optional) 2.2.1 Install power module 2.3 Install equipment and ground 2.4 Install SFP transceiver (optional)
Page 5
7.4 Network range 7.5 Power consumption / power output 8 Delivery item, order number and accessories 9 Basic technical standards A More support Installing MAMMUTHUS SWITCH Published on 01/2020...
Make sure there is no component to be repaired in the equipment. In case of any damage or failure to the equipment, switch off the power and return the equipment to Belden for inspection. Qualification requirements for operators Only qualified personnel are allowed to operate the equipment.
Page 7
Correct use Use the equipment only for the purposes specified in the catalog and technical instructions. Only external devices components recommended and permitted by the manufacturer can be used to operate the equipment. The correct and safe operation of this product depends on the correct operation, storage, assembly and installation during transport, as well as careful operation and maintenance procedures.
Page 8
Power cord diameter at the power supply voltage input shall be at least 0.75 mm² (North America: AWG18). The cross section of the grounding conductor shall be the same as or larger than that of the power cord. ...
Page 9
Special conditions for safe use Install the basic equipment and modules in a suitable enclosure based on specific environmental conditions to provide at least IP54 protection according to the requirements of EN 60529. Take measures to prevent instantaneous interference from exceeding 140% of the rated voltage at the voltage input.
Page 10
Equipment enclosure Only technicians authorized by the manufacturer are allowed to open the enclosure. Keep vents open to ensure good air circulation. Ensure a minimum of 3.94 inches (10 cm) of space in front of the enclosure vent. ...
Page 11
EU directives: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany www.belden.com Warning! As Class A equipment, it may cause interference to the living area. In such case, the operator may need to take appropriate actions. Warning! When Ethernet cables are used in industrial environments, they must be shielded.
Page 12
LED or Laser Component LED or Laser Component conforming to IEC 60825-1 (2014): Class 1 laser products Class 1 LED products FCC description: The equipment complies with Section 15 of FCC. The equipment shall be operated in line with the following two requirements: (1) the equipment causes no harmful interference;...
About the manual This user manual about “Installation” contains equipment instructions, safety instructions, display instructions, and other information required for equipment installation. Installing MAMMUTHUS SWITCH Published on 01/2020...
Legend The symbols used in this manual have the following meanings: Item list Work step Subtitle Installing MAMMUTHUS SWITCH Published on 01/2020...
Description General equipment description MTS2600 switch provides an economic choice for port expansion and LAN extension, which enables customers to choose products with good performance, function and flexibility under the condition of tight budget. Users can extend the Gigabit line speed switching performance from the core to access equipment.
Page 16
Installing MAMMUTHUS SWITCH Published on 01/2020...
Page 17
Power module You may choose 1 or 2 power modules with the same input voltage: LV / Ethernet power supply (+) Power modules are provided as accessories. Please refer to “Order number” on Page 68 . Installing MAMMUTHUS SWITCH Published on 01/2020...
Page 18
Media module You can select 1 media module. Media modules are provided as accessories. Please refer to “Order number” on Page 68. Installing MAMMUTHUS SWITCH Published on 01/2020...
Equipment view 1.3.1 MTS2624-4X-B Front view Gigabit Electrical Interface status LED Gigabit Electrical Interface 10 Gigabit Optical Interface USB interface CONSOLE port Equipment status LED Reset button (press and hold for 5 seconds to restart the machine) AC power socket Ground terminal 1.3.2 MTS2724-4X-FP-S...
Rear view AC power socket AC power socket Ground terminal 1.3.3 MTS2724-6X-MP-E Front view Gigabit Electrical Interface status LED Gigabit Electrical Interface (with POE function) 10 Gigabit Optical Interface USB interface CONSOLE port Equipment status LED Rear view Interface card slot Modular power supply 1 Modular power supply 2 Ground terminal...
1.3.4 MTS2748-6X-MP-E Front view Gigabit Electrical Interface status LED Gigabit Electrical Interface (with POE function) 10 Gigabit Optical Interface USB interface CONSOLE port Equipment status LED Rear view Interface card slot Modular power supply 1 Modular power supply 2 Ground terminal Installing MAMMUTHUS SWITCH Published on...
1.3.5 MTS2824-4X-S Front view Gigabit Electrical Interface status LED Gigabit Electrical Interface 10 Gigabit Optical Interface USB interface CONSOLE port Equipment status LED Reset button (press and hold for 5 seconds to restart the machine) Rear view AC power socket AC power socket Ground terminal Installing MAMMUTHUS...
1.3.6 MTS2824-6X-E Front view USB interface CONSOLE port Gigabit Electrical Interface status LED Gigabit Electrical Interface Air inlet of equipment 10 Gigabit Optical Interface status LED 10 Gigabit Optical Interface Equipment status LED Rear view Air outlet of equipment AC power socket Ground terminal Installing MAMMUTHUS SWITCH...
1.3.7 MTS2824F-4X-S Front view Air inlet of equipment Gigabit Optical Interface status LED Gigabit Optical Interface 10 Gigabit Optical Interface USB interface CONSOLE port Equipment status LED Reset button (press and hold for 5 seconds to restart the machine) Rear view AC power socket AC power socket Ground terminal...
1.3.8 MTS2832TF-4X-E Front view Gigabit Optical Interface status LED Gigabit Optical Interface Gigabit Electrical Interface status LED Gigabit Electrical Interface 10 Gigabit Optical Interface status LED 10 Gigabit Optical Interface CONSOLE port USB interface Equipment status LED Rear view AC power socket AC power socket Ground terminal Installing MAMMUTHUS...
1.3.9 MTS2848-6X-E Front view USB interface CONSOLE port Gigabit Electrical Interface status LED Gigabit Electrical Interface Air inlet of equipment 10 Gigabit Optical Interface status LED 10 Gigabit Optical Interface Equipment status LED Rear view Air outlet of equipment AC power socket Ground terminal Installing MAMMUTHUS SWITCH...
1.3.10 MTS2848-6X-S Front view USB interface CONSOLE port Gigabit Electrical Interface status LED Gigabit Electrical Interface Air inlet of equipment 10 Gigabit Optical Interface status LED 10 Gigabit Optical Interface Equipment status LED Rear view Air outlet of equipment AC power socket Ground terminal Installing MAMMUTHUS SWITCH...
Power supply You may use the power module to supply voltage to the equipment: See the “Power module” on page for information about connecting supply voltage. Installing MAMMUTHUS SWITCH Published on 01/2020...
Ethernet port You may use twisted pair or fiber optic (F/O) cables to connect terminal devices and other network segments to the equipment and the media module ports. 1.5.1 1000 Mbit/s F/O port The port is an SFP slot. The port allows you to connect network components according to IEEE 802.3 1000BASE-SX/1000BASE-LX.
SNMP SSH Telnet FTP See the “Command line interface user manual” for more information. You may download the manual on the product page of Hirschmann IT at https://hirschmann-it.support.belden.com. Installing MAMMUTHUS SWITCH Published on 01/2020...
Display unit After the power supply voltage is set, the software will start automatically and complete initialization. And then the equipment performs self-test. All LED indicators will come on in this process. 1.6.1 Equipment status These LEDs provide information about the conditions that affect the operation of the equipment.
1.6.2 Port Status These LEDs provide port information. Indicator Indicator Indicator color Status type name RJ45 Flashing: indicating data sending on serial port self-contained OFF: indicating no data sending on serial port Serial port yellow LED indicator RJ45 Build-in Flashing: indicating data receiving on serial port green LED OFF: indicating no data receiving on serial port RJ45...
Management interface 1.7.1 DC0 interface (external management) The serial interface is provided on RJ45 socket (V.24 interface), which can realize the local connection of external management station (VT100 terminal or PC with corresponding terminal simulation), and thus you are allowed to establish the connection to the command line interface CLI and the system monitor.
Installation These devices are developed for use in commercial environments. At the time of delivery, the equipment is ready for operation. Follow the following steps to install and configure the equipment: Unpack the box for inspection Install cover plate and power module (optional) ...
Install equipment and ground You can install the equipment by the following options: Install the equipment in the switch cabinet Install the equipment on a vertical flat surface Warning Electric shock Such equipment can only be installed in switch cabinet or restricted operation place, and the equipment is accessible to maintenance personnel only.
Follow the steps below: Install sliding or mounting rails in a 19 "switch cabinet as specified by the manufacturer. Place the equipment on the rail in the switch cabinet. Screw the mounting bracket to the switch cabinet to secure the equipment. ...
Operate equipment Follow the steps below: Use screws to secure the connector to the equipment. You can refer to the specified tightening torque in the “General technical data” on page 49. Enable the supply voltage. Connect data cable In environments with high electrical interference, note the following general recommendations for data cable connections: ...
Make basic settings Note: Configuring two or more devices with the same IP address may lead to the network’s failure to function as expected. Install and maintain a program, to assign a unique IP address to each device in the network. IP parameters must be entered when the equipment is installed for the first time.
Monitor ambient air temperature Please operate the equipment only below the specified maximum ambient air temperature. Please refer to “General technical data” on Page 49. The ambient air temperature is the air temperature at a distance of 2 inches (5 cm) from the equipment, specifically depending on the installation conditions of the equipment, for example, the distance of the equipment from other devices or other objects, and the output of adjacent equipment.
You may view the information and download software on the product page of Hirschmann IT at https://hirschmann-it.support.belden.com Depending on the pollution level in the operating environment, regularly check whether the ventilation slot in the equipment is blocked.
Remove Remove power module Follow the steps below: Remove screws on the front panel of the power module. Pull the power module out of the slot. Seal the power module slot on the basic device with a cover plate. ...
Remove SFP transceiver Follow the steps below: Unlock and pull the SFP transceiver out of the slot. Seal the SFP transceiver with a protective cover. Installing MAMMUTHUS SWITCH Published on 01/2020...
Remove device Warning Electric shock Please disconnect all other cables before disconnecting the ground wire. Failure to comply with these guidelines may result in death, serious injury or equipment damage. Follow the steps below: Disconnect the data cable. Disable the supply voltage.
Technical data General technical data Basic device Size Please refer to “Size diagram” on Page 40. Weight MTS2624-4X-B < 2.8kg MTS2724-4X-FP-S < 5.5kg MTS2724-6X-MP-E < 6.0kg MTS2748-6X-MP-E < 6.0kg MTS2832TF-4X-E < 4.0kg MTS2824F-4X-S < 5.0kg MTS2824-4X-S < 3.0kg MTS2848-6X-S <...
Page 50
Power module Size Please refer to “Size diagram” on Page 40. Weight MTM2700-PSU120 0.9 kg MTM2700-PSU500 1.2 kg Installation Tighten torque 3.5~5.2 lb-in (0.4~0.6 Nm) power module Installation Tighten torque 3.5~5.2 lb-in (0.4~0.6 Nm) cover plate Power module Rated voltage range 100 VAC...240 VAC, 50 Hz.
EMC and immunity EMC interference emission Standard application EN 55032 Class A DNV GL Guide — FCC 47 CFR Part 15 Class A EN 61000-6-4 Conforming EN 55032 AC/DC Power Line Class A DNV GL Guide AC/DC Power Line — FCC 47 CFR Part 15 AC/DC Power Line Class A...
Page 64
EMC immunity Standard application Electromagnetic field EN 61000-4-3 80 MHz...1000 MHz 10 V/m 1000 MHz...6000 MHz 3 V/m IEEE 1613 80 MHz...1000 MHz — Fast transient (burst) EN 61000-4-4 AC/DC Power Line ±2 kV IEEE C37.90.1 EN 61000-4-4 Data cable ±1 kV IEEE C37.90.1 EN 61000-4-5...
Page 65
EMC immunity Standard application Damped vibration - AC/DC Power Line EN 61000-4-12 Cable / ground — IEEE C37.90.1 EN 61000-4-12 Cable / cable — IEEE C37.90.1 Damped oscillation - data cable EN 61000-4-12 Cable / ground — IEEE C37.90.1 EN 61000-4-12 Cable / cable —...
Network range Note: The line length specified for the transceiver applies to the corresponding fiber data (fiber attenuation and BLP/dispersion). Product code Mode Optical BLPc/dispersio Wave length F/O cable length example MTS-SFP-1G-... attenuation TX/RJ Full Duplex -TX/RJ45... 100 m Negotiation 550 m (>...
Power consumption / power output Name Maximum power consumption Basic device + 1 PSU MTS2624-4X-B 26 W MTS2724-4X-FP-S 29 W MTS2724-6X-MP-E 34 W MTS2748-6X-MP-E 46 W MTS2832TF-4X-E 60 W MTS2824F-4X-S 38 W MTS2824-4X-S 26 W MTS2848-6X-S 55 W MTS2824-6X-E 37 W MTS2848-6X-E 55 W Installing MAMMUTHUS...
Order number MTS-SFP-10G-SR/LC 942 999 851 MTS-SFP-10G-LR/LC 942 999 852 MTS-SFP-10G-ER/LC 942 999 853 MTS-SFP-10G-TX/RJ45 942 999 867 a. You may access more information about certificates on the product page of Hirschmann IT (https://hirschmann-it.support.belden.com). Installing MAMMUTHUS SWITCH Published on 01/2020...
Basic technical standards Name FCC 47CFR Part 15 Code of Federal Regulations IEC 60825-1 Safety of Laser Products IEC/EN 61850-3 Communication networks and systems for power utility automation - Part 3: General requirements IEEE 1613 IEEE Environmental and Testing Requirements for Communications Networking Devices Installed in Electrical Power Substations IEEE 802.3 Ethernet...
Page 70
The equipment usually meets the technical standards set forth in the latest version. Only when the equipment shell has the certification mark, it means that the equipment is certified to a specific standard. Installing MAMMUTHUS SWITCH Published on 01/2020...
A More support Technical issues If you have any technical question, please contact your local Hirschmann IT dealer or Belden directly. search partners’ addresses online https://hirschmann-it.support.belden.com. For the list of local telephone numbers and email addresses for you to get...
Page 72
Installing MAMMUTHUS SWITCH Published on 01/2020...
Need help?
Do you have a question about the Hirschmann MAMMUTHUS MTS2600 and is the answer not in the manual?
Questions and answers