Output Terminal Group:f2.00-F2.19 - Powtran PI500-E Series Manual

Table of Contents

Advertisement

Chapter 5 Function parameter
5-2-4.Output terminal group:F2.00-F2.19
Code
Parameter name
SPB terminal output
F2.00
selection
SPB terminals are programmable multiplex terminal can be used as high-speed pulse output
terminal, it can also be used as open collector output terminal.
As a high-speed pulse output, the maximum frequency of the output pulse is 100kHz, high-
speed pulse output of the correlation function refer to Note F2.06.
Switching quantity output function selection (Open collector output
F2.01
terminal)
F2.02 Relay 1 output function selection (TA1.TB1.TC1)
F2.03 Undefined
SPA output function selection (collector open circuit output
F2.04
terminals)
F2.05 Relay 2 output function selection (TA2.TB2.TC2)
Above 5 function code is used to select five digital output function. Multifunctional output
terminal functions are as follows:
Setting
Functions
value
No output
0
Inverter running
1
Fault output (fault down ) When the drive fails and downtime, the output ON signal.
2
Frequency level detection
3
FDT1 output
Frequency arrival
4
Zero-speed running (no
5
output when shutdown)
Motor overload pre-alarm
6
Inverter overload pre-
7
alarm
Setup counter arrive
8
Specifies the count value
9
reaches
Length arrival
10
PLC cycle is complete
11
Total running time arrival
12
Limited in frequency
13
Torque limiting
14
Setting range
High speed pulse output
Switching output
No output action
Inverter is in running state, the output frequency (can be zero),
the output ON signal.
Please refer to the function code F7.23, F7.24's instructions.
Please refer to the description of function code F7.25.
Inverter operation and the output frequency is 0, output ON
signal. When the drive is shut down, the signal is OFF.
Before the motor overload protection, according to the
overload pre-alarm threshold value judgment, more than the
pre-alarm threshold value output ON signal. Motor overload
parameter settings refer to the function code F8.02 ~ F8.04.
Before the inverter overload occurs 10s, output ON signal.
Setup counter arrive
When the count reaches the set value of E0.08, output ON
signal.
Specifies the count value reaches
When the count reaches the set value of E0.09, output ON
signal. Counting Function Reference E0 group
When the actual length of the detection of more than E0.05 set
length, output ON signal.
After simple PLC completes one cycle, the output of a pulse
width of 250ms signal.
Inverter total running time of more than F7.21 F6.07 set time,
the output ON signal.
When the set frequency exceeds the upper limit frequency or
lower frequency, and output frequency is beyond the upper
limit frequency or lower limit frequency, output ON signal.
Drive under the speed control mode, when the output torque
72
Factory
setting
0
1
0~40
0~40
0~40
0~40
Description
Cha
nge
0
0
2
1
1