EnDat
You can configure the TJ1-FL02 to
interface directly to EnDat absolute
encoders. EnDat absolute encoders
respond on a dedicated Clock and
Data 1 MHz RS485 serial interface
when their position is requested by
Encoder signal
Axis A
DATA
6
/DATA
7
CLOCK
1
/CLOCK
2
GND
5 / 15
Note
The TJ1-FL02 does not have a termination inside. In case of long
distances or disturbed communication, add an external termination
to the TJ1-FL02.
The table below and the figure give
an example of how to connect the
Heidenhain ROC 425 2048 5XS08-
C4 encoder to the TJ1-FL02.
Encoder
Pin
Signal
Wire color
3
DATA
Grey
4
/DATA
Pink
7
CLOCK
Violet
6
/CLOCK
Yellow
5
GND
White/Green
HARDWARE REFERENCE MANUAL
the controller. When you set the
encoder to the relevant encoder
mode, the axis transmits an
information request to the encoder
on a fixed 250 µs cycle.
The connections for EnDat are:
/i
Axis B
8
9
11
12
5 / 15
/i
TJ1-FL02
Pin
Signal
6
DATA
7
/DATA
1
CLOCK
2
/CLOCK
5
GND
fig. 121
TJ1-FL02
3
6
4
7
7
1
6
2
5
5
2
1
5 V
0 V
5 VDC Power Supply