Safety Instructions - Smeg Linea PX7502AU Manual

Table of Contents

Advertisement

3. Additional requirements for Free-
standing and Elevated Cooking
Appliances – (Measurements D & E)
Where D, the distance from the
periphery of the nearest burner to a
horizontal combustible surface is less
than 200 mm, then E shall be 10 mm or
more, or the horizontal surface shall be
above the trivet. See insets above.
Notes
1. Requirement 3 does not apply to a free-
standing or elevated cooking appliance
which is designed to prevent flames or
the cooking vessels from extending
beyond the periphery of the appliance.
2. The 'cooking surface area' is defined as
that part of the appliance where cooking
normally takes place and does not
include those parts of the appliance
containing control knobs.
3. For definition of hob, see Clause 1.4.64.
4. For definition of trivet, see Clause
1.4.109.
5. Consideration is to be given to window
treatments when located near cooking
appliances. See Clause 5.3.4.
The appliance connection point
shall be accessible with the
appliance installed.
Installation

5.2 Safety instructions

Heat production during appliance
operation
Risk of fire
• Make sure that the cabinet material is
heat resistant.
• Check that the cabinet has the required
slots.
Veneers, adhesives or plastic coatings on
adjacent furniture should be temperature-
resistant (>90°C), otherwise they might
warp over time.
The minimum clearance between a
ventilation hood and the cooking
surface must be at least the
distance indicated in the ventilation
hood installation instructions.
The minimum clearances must also be
respected for the edges of the cooktop on
the back as indicated in the mounting
illustrations.
19