4. Unscrew the cooktop fastening screws
and the burner support plates.
5. Remove the casing fastening screws.
6. Remove the top.
When reassembling, once the
cooktop is in the correct position,
press the previously mentioned
points in order to engage the push-
on connectors.
Installation
Replacing injectors and primary air
adjustment
1. Loosen the screw A and push the air
regulator B all the way down.
2. Use a spanner to remove the injectors C
and install the new ones for the type of
gas required, following the indications
given in the relevant table (see "Burner
and injector specifications tables").
The injector tightening torque must
be no more than 3 Nm.
3. Adjust the airflow by moving the air
regulator B to obtain the distance D
indicated in the relative table (see
"Burner and injector specifications
tables").
4. After adjusting each burner, reassemble
the appliance correctly.