Lenovo ThinkSystem SR630 V2 Reference page 73

Hide thumbs Also See for ThinkSystem SR630 V2:
Table of Contents

Advertisement

4. Disable the watchdog.
5. Check the integrity of the installed operating system.
6. If problem persists, collect Service Data log.
7. Contact Lenovo Support.
• FQXSPOS4003I: Platform Watchdog Timer expired for [arg1].
An implementation has detected an OS Loader Watchdog Timer Expired
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Loader timeout
SNMP Trap ID: 26
CIM Prefix: IMM CIM ID: 0060
User Action:
Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the BMC Ethernet over USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
5. If problem persists, collect Service Data log.
6. Contact Lenovo Support.Check the integrity of the installed operating system.
• FQXSPOS4004I: Operating System status has changed to [arg1].
Operating System status change
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0191
User Action:
Information only; no action is required.
• FQXSPOS4005I: Host Power-On password changed by user [arg1] from [arg2] at IP address [arg3].
This message is for the use case where Host Power-On password changed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0231
User Action:
Information only; no action is required.
• FQXSPOS4006I: Host Power-On password cleared by user [arg1] from [arg2] at IP address [arg3].
.
Chapter 2
XClarity Controller events
69