Severity: Error
User Action:
Complete the following steps:
1. Review XCC logs for communication errors and resolve.
2. AC cycle the system.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
• FQXSFSR0001M: [arg1] GPT corruption detected, DiskGUID: [arg2]
Severity: Warning
User Action:
Complete the following steps:
1. Remove all the external drive during POST to avoid this event false triggered.
2. Check the XCC event log, if this event has a follow up recovery event log, means GTP corruption has
been recovered successfully, then ignore this event message and do not perform the remaining
steps.
3. Back up the data disk.
4. Press F1 Setup->SystemSettings->Recovery->Disk GPT Recovery and set to "Automatic."
5. Save settings and restart the system.
6. Boot to F1 setup; system automatically tries to recover the GPT during the POST.
7. Restart the system.
8. Re-format the LUN or disk and re-install the OS.
9. If the problem persists, collect Service Data logs.
10. Contact Lenovo Support.
• FQXSFSR0002I: [arg1] GPT corruption recovered, DiskGUID: [arg2]
Severity: Info
User Action:
Information only; no action is required.
• FQXSFSR0003G: The number of boot attempts has been exceeded. No bootable device found.
Severity: Warning
User Action:
Complete the following steps:
1. Remove AC power from the system.
2. Connect at least one bootable device ot the system.
3. Connect AC power to the system.
4. Power on system and retry.
5. If the problem persists, collect Service Data logs.
6. Contact Lenovo Support.
• FQXSFTR0001L: An invalid date and time have been detected.
Severity: Warning
.