Lenovo ThinkSystem SR630 V2 Reference page 196

Hide thumbs Also See for ThinkSystem SR630 V2:
Table of Contents

Advertisement

Severity: Error
User Action:
1. Reboot system and run the test again later.
2. If this message is still reported, please run the latest version of SMART tool on OS which is open
source tool and could be downloaded from website to check hard drive status.
3. If the problem persists, please contact technical support.
• FQXPMSD0010M: uEFI is timeout while LXPM send command to test hard drive.
Severity: Error
User Action:
1. Reboot system and run the test again later.
2. If this message is still reported, please run the latest version of SMART tool on OS which is open
source tool and could be downloaded from website to check hard drive status.
3. If the problem persists, please contact technical support.
• FQXPMSD0011M: The hard drive is not supported by uEFI while LXPM send command to test hard
drive.
Severity: Error
User Action:
1. Please check hard drive specification to see if the hard drive support ATA self-test feature.
2. If the problem persists, please contact technical support.
• FQXPMSR0001K: Found unsupported RAID adapter.
Severity: Warning
User Action:
1. Check the following Lenovo support site for information on supported RAID adapters. http://www.
lenovo.com/us/en/serverproven/index.shtml
2. Ensure RAID adapter, LXPM, and UEFI firmware are at the latest levels.
3. If the problem persists, please contact technical support.
• FQXPMSR0011K: Failed to change disk drives' state.
Severity: Warning
User Action:
1. Ensure LXPM and RAID adapter firmware are at the latest levels.
2. Ensure the state of the RAID adapter and disk drives are both healty.
3. Verify proper physical connection of the disk drive, SAS expander (if applicable) and RAID adapter.
4. Ensure the operation to the special drive is legal or logical. (For example, you cannot change
Unconfigured BAD to Online satus)
5. Reboot the machine and retry to change disk drives' state.
6. If the problem persists, please contact technical support.
• FQXPMSR0012I: Change disk drives' state successfully.
Severity: Info