v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8849 and Type 8491 server," on page 19 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
System-error log message
Configuration error recovery on the interconnect
network
CPU over temperature.
DASD controller removal
DHCP failure, no IP@ assigned-RETRYING!,
rc=xxx, count=yyy
Dialback failed for userid x. Could not connect at
phone number yyy yyy yyyy
ENET[eee] DHCP-HstNme=a, DN=b,
IP@=ccc.ccc.ccc.ccc GW@=ddd.ddd.ddd.ddd,
NMsk=fff.fff.fff.fff, DNS1@=ggg.ggg.ggg.ggg,
DNS2@=hhh.hhh.hhh.hhh
ENET[eee] IP-Cfg: HstName=x,
IP@=ccc.ccc.ccc.ccc, GW@=ddd.ddd.ddd.ddd,
NetMsk=fff.fff.fff.fff
Failure reading an I2C device, possible bus
failure.
Fan x Outside Recommended Speed.
102
IBM xSeries 306m Types 8849 and 8491: Problem Determination and Service Guide
Action
Information only.
1. Make sure that the fans have good airflow and are not
obstructed.
2. (Trained service technician only) Reseat the microprocessor
heat-exchanger assembly.
1. Check the following cables for damage. Make sure that the
cables are not broken, crimped, or caught by any components.
v (Hot-swap models only) The cable from the SAS/SATA
controller to the hard disk drive backplane. If this cable is
damaged, replace the cable.
v (Simple-swap models only) The cables from the hard disk
drive back panel to the SATA connectors on the system
board. If either of these cables is damaged, replace the back
panel.
v The power cable or cables to the hard disk drive backplane
or back panel. If this cable is damaged, replace the power
supply.
2. Reseat the cables listed in step 1, restarting the server after
reseating all cables.
Information only.
Information only.
Information only.
Information only.
1. Reseat the following components:
a. AC power cord
b. (Trained service technician only) System board
c. (Trained service technician only) Power supply
2. (Trained service technician only) Replace the system board.
1. Make sure that fan x is not obstructed:
2. Reseat the following components:
a. Fan x
b. Fan x cable
3. Replace fan x.