11.8 Alarm Linkage Actions

Purpose:
Alarm linkage actions will be activated when an alarm or exception occurs, including Event Hint
Display, Full Screen Monitoring, Audible Warning (buzzer), Notify Surveillance Center, Trigger
Alarm Output and Send Email.

11.8.1 Configure Auto-switch Full Screen Monitoring

When an alarm is triggered, the local monitor displays in full screen the video image from the
alarming channel configured for full screen monitoring. And when the alarm is triggered
simultaneously in several channels, you must configure the auto-switch dwell time.
Step 1 Go to System > View > General.
Step 2 Set the event output and dwell time.
 Event Output: Select the output to show event video.
 Full Screen Monitoring Dwell Time: Set the time in seconds to show alarm event screen. If
alarms are triggered simultaneously in several channels, their full-screen images will be
switched at an interval of 10 seconds (default dwell time).
Step 3 Go to the Linkage Action interface of the alarm detection (e.g., motion detection, video
tampering, face detection, etc.).
Step 4 Select the Full Screen Monitoring alarm linkage action.
Step 5 Select the channel(s) in Trigger Channel settings you want to make full screen monitoring.
Auto-switch will terminate once the alarm stops and back to the live view interface.

11.8.2 Configure Audio Warning

The audio warning enables the system to trigger an audible beep when an alarm is detected.
Step 1 Go to System>View>General.
Step 2 Enable the audio output and set the volume.
Step 3 Go to the Linkage Action interface of the alarm detection (e.g., motion detection, video
tampering, face detection, etc.).
Step 4 Select the Audio Warning alarm linkage action.

11.8.3 Notify Surveillance Center

The device can send an exception or alarm signal to the remote alarm host when an event occurs.
The alarm host refers to the PC installed with client software (e.g., iVMS-4200, iVMS-5200).