Procedure 2: Inspecting A Cartridge For Damage - IBM System Storage TS2250 Setup, Operator, And Service Manual

Hide thumbs Also See for System Storage TS2250:
Table of Contents

Advertisement

The ITDT utility (see "ITDT firmware update, dump retrieval and library/drive
test tool" on page 2-7) can be used to update the firmware level as well as to
capture a drive dump which may be requested by technical support to aid in
problem analysis.
For instructions about updating firmware from a server that uses an IBM tape
device driver, refer to the IBM Tape Device Drivers Installation and User's Guide.
To update firmware from a server that uses a non-IBM tape device driver, refer to
the documentation for that device driver.
Perform the following steps to determine the current firmware level installed on
the drive.
1. Use the ITDT utility (available on the web at http://www.ibm.com/support/
2. Compare this level with the latest available firmware level by visiting the same
Another way to capture a drive dump is using the ethernet port. To capture a
dump on the drive using the Ethernet interface follow the steps below.
Note: The drive uses a limited version of FTP protocol to communicate on the
1. Obtain the latest drive firmware from the web, as described above.
2. Connect an ethernet patch cable to the drive's ethernet interface and to a
3. Create an FTP session between the drive and the computer. The drive's IP
4. At the user prompt, type guest and press Enter.
5. At the password prompt, press Enter. No response is needed.
6. Type bin to set the communication mode to binary.
7. Type mget *.dmp to transfer a drive dump to the computer. If a dump already
8. Type quit to end the FTP session.
9. Remove ethernet patch cable from the drive's ethernet interface and the

Procedure 2: Inspecting a Cartridge for Damage

If the cartridge fails to load or unload properly, perform the following steps:
5-2
TS2250 Tape Drive Setup, Operator and Service manual
fixcentral) to view the current drive firmware level.
website. For additional information about using the ITDT utility, see "Updating
firmware" on page 2-7.
Note: The ITDT utility can be used to either update drive firmware to the
latest level or to capture drive dumps from a drive which may be
experiencing problems.
Ethernet interface. It is recommended to use a simple, command line FTP
session, such as the DOS command prompt, when communicating with the
drive.
computer. In order to meet electromagnetic immunity requirements, a shielded
ethernet cable is required.
address: 169.254.0.3
exists, the drive will show you the dump name and ask if you want to transfer
it to the computer. Type y to transfer the existing dump or n to skip this dump
file. Then the drive will ask if you want a forced dump. Type y to force a dump
and to transfer the forced dump to the computer, or type n to skip forcing a
dump.
computer.