ensto ECO16LCDJR Manual page 6

Combination thermostat
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
8. USER MENU
Enter the user menu: Select
Maintain the joystick on the left direction
Select the parameter you want to adjust with the joystick
Confirm selection by pressing the joystick
The current value is blinking. Now you can adjust the value with the joystick
Save by pressing the joystick
Restore the factory setting for the selected parameter by pressing the return button
Parameter
No
Name
Parameter description
01
SEnS
Sensor selection
Calibrate internal sensor.**
Procedure: Before calibration, operate the thermo-
stat with same temperature setting for at least one
day. Put a thermometer at the same height as the
CAL
thermostat (approx. 1.5 m above the floor) and give it
02
enough time to stabilize. Press the joystick and enter
Air
the value that is read out from the thermometer. Save
by pressing the joystick.
Note! The heating element managed by the thermo-
stat must be in operation during the calibration.
Calibrate external sensor.
Procedure: Before calibration, operate the thermo-
stat with same temperature setting for at least one
day. If the external sensor is used as floor sensor, put
CAL
the thermometer on the floor and give it enough time
03
to stabilize. Press the joystick and enter the value that
SoL
is read out from the thermometer. Save by pressing
the joystick.
Note! The heating element managed by the thermo-
stat must be in operation during the calibration.
Drying function for concrete floors.
When activated, this function starts a drying program
that lasts for 21 days. During the first 24 hours the
1rst
heating is on 2 hours totally. For each following day,
04
Heat
another 1 hour of heating is added. The temperature
is limited to 20 ⁰C during the program. The function is
not stopped due to possible power breaks.
Connected load [W] to the thermostat.
Connect max. 2300W load, when the internal sensor
is selected.
05
LoAd
If you connect a load 2300W - 3600W, use an exter-
nal power relay (contactor). Adjust the parameter to
"0000".
Exit the user menu.
End
09
The program version is displayed.
* Alternative settings depend on parameter 14 in the installers menu.
** The parameter is not shown if another sensor is selected.
6
with the joystick.
for 5 seconds.
RAK126 / © Ensto 2019
User menu
Factory setting
Sens Air Only
Internal sensor
no
Not calibrated
no
Not calibrated
no
Not activated
1500
Press the joystick
Alternative
setting
Sens Flor Only*
External sensor
done
Calibrated
done
Calibrated
21
Activated
Adjustable 0 to
2300 in steps
of 50