Specifications - Omron S8VS-01505 Manual

Switch mode power supply
Hide thumbs Also See for S8VS-01505:
Table of Contents

Advertisement

Specifications

Ratings/Characteristics
Item
Efficiency
Voltage *1
Frequency *1
Current
Power factor
Input
Harmonic current regulation
Leakage current
Inrush current *2
Voltage adjustment range *3
Ripple noise voltage (at rated I/O)
Input variation influence
Load variation influence
(rated input voltage)
Output
Temperature variation influence
Startup time
(at rated I/O) *2
Output hold time
(at rated I/O) *2
Overload protection *2
Overvoltage protection *2
Output voltage indication
Output current indication
Peak-hold current indication
Maintenance forecast monitor indication
Additional
Maintenance forecast monitor output
functions
Total run time monitor indication
Total run time monitor output
Undervoltage alarm indication
Undervoltage alarm output
Parallel operation
Series operation
Operating ambient temperature
Storage temperature
Operating ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
Other
EMI
EMS
Approved standards
SEMI
Weight
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on page 18 for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting
the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Arrow.com.
Arrow.com.
Arrow.com.
Downloaded from
Downloaded from
Downloaded from
Power ratings
Output voltage
5 V
With 100-VAC input
74% typical
With 200-VAC input
73% typical
100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *5)
50/60 Hz (47 to 450 Hz)
With 100-VAC input
0.45 A max., 0.34 A typical
With 200-VAC input
0.25 A max., 0.22 A typical
---
Conforms to EN61000-3-2
With 100-VAC input
0.5 mA max.
With 200-VAC input
1.0 mA max.
With 100-VAC input
17.5 A max., 14 A typical
With 200-VAC input
35 A max., 28 A typical
−10% to 15% (with V.ADJ)
60 mV max.
0.5% max. (at 85- to 264-VAC input, 100% load)
2.0% max. (5 V), 1.5% max. (12 V, 24 V), (with rated input, 0 to 100% load)
0.05%/°C max.
With 100-VAC input
580 ms typical
With 200-VAC input
340 ms typical
With 100-VAC input
39 ms typical
With 200-VAC input
187 ms typical
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Yes *4
No
No
No
No
No
No
No
Yes (color: red)
No
No (However, backup operation is possible. An external diode is required.)
Models with 24-V output: Possible for up to 2 Power Supplies (with external diode)
Models with 5- or 12-V output: Not possible
Refer to the derating curve in Engineering Data. (with no icing or condensation)
−25 to 65°C
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
100 MΩ min. (between all outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
2
150 m/s
, 3 times each in ±X, ±Y, and ±Z directions
Yes (color: green)
Conducted
Conforms to EN55011 Group1 Class B and based on FCC Class A
Emissions
Radiated Emissions
Conforms to EN55011 Group1 Class B
Conforms to EN61204-3 high severity levels
UL 508 (Listing, Class2 Output: Per 1310)
UL 60950-1, UL 62368-1
CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223)
CSA C22.2 No.60950-1 (cUR), No.62368-1
EN 50178, EN 60950-1, EN 62368-1
EAC mark, RCM mark
F47-0706 (With 200-VAC input)
160 g max.
15 W
12 V
24 V
79% typical
83% typical
74% typical
78% typical
80% typical
74% typical
0.9 A max., 0.66 A typical
0.6 A max., 0.4 A typical
70 mV max.
60 mV max.
60 mV max.
530 ms typical
600 ms typical
500 ms typical
360 ms typical
400 ms typical
360 ms typical
27 ms typical
28 ms typical
31 ms typical
134 ms typical
134 ms typical
174 ms typical
180 g max.
S8VS
30 W
5 V
12 V
24 V
81% typical
85% typical
80% typical
86% typical
90 mV max.
150 mV max.
560 ms typical
560 ms typical
380 ms typical
400 ms typical
22 ms typical
31 ms typical
123 ms typical
140 ms typical
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents