Specifications - Omron D4NS Quick Start Manual

Safety-door switch
Hide thumbs Also See for D4NS:
Table of Contents

Advertisement

Specifications

Standards and EC Directives
Conforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60947-5-1
• EN ISO 14119
• GS-ET-15
Certified Standards
Certification body
Standard
EN60947-5-1
TÜV SÜD
(certified direct opening)
UL *1
UL508, CSA C22.2 No.14
CQC (CCC)
GB/T 14048.5
KOSHA *2
EN60947-5-1
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Only certain models have been certified.
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB/T 14048.5)
Utilization
Item
category
Rated operating current (I
)
e
Rated operating voltage (U
)
e
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a
short-circuit protection device. This fuse is not built into the
Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated
Carry current
voltage
Make
120 VAC
10 A
240 VAC
Q300
Rated
Carry current
voltage
Make
125 VDC
0.55
2.5 A
250 VDC
0.27
Characteristics
Interlock type
Coding level
Degree of protection *1
Durability *2
Mechanical
Electrical
Operating speed
File No.
Consult your
OMRON representative
for details.
E76675
Consult your
OMRON representative
for details.
Consult your
OMRON representative
for details.
AC-15
DC-13
3 A
0.27 A
240 V
250 V
Current (A)
Volt-amperes (VA)
Break
Make
Break
60
6
7,200
720
30
3
Current (A)
Volt-amperes (VA)
Break
Make
Break
0.55
69
69
0.27
Type 2 (EN ISO 14119)
Low level coded (EN ISO 14119)
IP67 (EN60947-5-1)
<Standard type>
1,000,000 operations min.
<High pull-force type>
100,000 operations min.
<Standard type>
500,000 operations min. (3 A
resistive load at 250 VAC) *3
300,000 operations min. (10 A
resistive load at 250 VAC)
<High pull-force type>
100,000 operations min. (10 A
resistive load at 250 VAC)
0.05 to 0.5 m/s
Direct opening force *4
Direct opening travel *4
Contact resistance
Minimum applicable load *5
Rated insulation voltage (U
)
i
Rated frequency
Protection against electric
shock
Pollution degree (operating
environment)
Impulse
Between
withstand
terminals of
voltage (Uimp)
same polarity
(EN60947-5-1)
Between
terminals of
different
polarity
Between each
terminal and
non-current
carrying
metallic parts
Insulation resistance
Contact gap
Vibration
Malfunction
resistance
Shock
Destruction
resistance
Malfunction
Conditional short-circuit
current
Conventional free air thermal
current (I
)
th
Ambient operating
temperature
Ambient operating humidity
Weight
Note: 1. The above values are initial values.
2. The Switch contacts can be used with either standard loads
or microloads. Once the contacts have been used to switch
a load, however, they cannot be used to switch smaller
loads. The contact surfaces will become rough once they
have been used and contact reliability for smaller loads may
be reduced.
*1. The degree of protection is tested using the method specified by
the standard (EN60947-5-1). Confirm that sealing properties are
sufficient for the operating conditions and environment
beforehand. Although the switch box is protected from dust or
water penetration, do not use the D4NS in places where foreign
material may enter through the key hole on the head, otherwise
Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an
ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This value will vary with the switching frequency, environment,
and reliability level. Confirm that correct operation is possible with
the actual load beforehand.
D4NS/D4NS-SK
<Standard type>
60 N min.
<High pull-force type>
80 N min.
10 mm min.
25 mΩ max.
1 mA resistive load at 5 VDC (N-
level reference value)
300 V
50/60 Hz
Class II (double insulation)
3 (EN60947-5-1)
2.5 kV
4 kV
6 kV
100 MΩ min.
2 × 2 mm min.
10 to 55 Hz, 0.75 mm single
amplitude
1,000 m/s
2
min.
300 m/s
2
min.
100 A (EN60947-5-1)
10 A (EN60947-5-1)
−30 to 70°C (with no icing)
95% max.
Approx. 96 g (D4NS-1CF)
5