Download Print this page
Whisper Power Supreme Combi 230V Series User Manual

Whisper Power Supreme Combi 230V Series User Manual

Inverter/ charger

Advertisement

Quick Links

User Manual
Inverter/ Charger
Supreme Combi
E n j o y G r e e n E n e r g y
24 VDC - 3000 VA | 24 VDC - 2000 VA | 230 VAC - 50 Hz
whisperpower.com

Advertisement

loading

Summary of Contents for Whisper Power Supreme Combi 230V Series

  • Page 1 User Manual Inverter/ Charger Supreme Combi E n j o y G r e e n E n e r g y 24 VDC - 3000 VA | 24 VDC - 2000 VA | 230 VAC - 50 Hz whisperpower.com...
  • Page 3 WhisperPower Inverter / Battery Charger Inverter-Charger 230V Series 24V-2000W-40A (61242040) 24V-3000W-50A (61243050) User Manual Manual edition 2022.02.04...
  • Page 4 Important Please be sure to read and save the entire manual before using your Whisper Power Sinewave Inverter-Charger. Misuse may result in damage to the unit and/or cause harm or serious injury. Read manual in its entirety before using the unit and save manual for future reference.
  • Page 5 WhisperPower Inverter / Battery Charger IMPORTANT SAFETY INFORMATION This section contains important safety information for the Sinewave Inverter-Charger. Before using the unit, READ ALL instructions and cautionary markings on or provided with the unit, and all appropriate sections of this guide. The Sinewave Inverter-Charger contains no user-serviceable parts.
  • Page 6 WhisperPower Inverter / Battery Charger • Prolonged exposure to high heat or freezing temperatures will decrease the working life of the unit. • DO NOT connect AC power sources like utility power or generator to the AC outputs of the unit. It will damage the unit and may cause fire. Feeding AC to the AC output of the unit is not covered by warranty.
  • Page 7: Table Of Contents

    WhisperPower Inverter / Battery Charger TABLE OF CONTENTS INTRODUCTION PRODUCT DESCRIPTION UNDERSTANDING THE UNIT INSTALLING THE UNIT UNIT OPERATION TROUBLESHOOTING SPECIFICATIONS WARRANTY...
  • Page 8: Introduction

    WhisperPower Inverter / Battery Charger 1. INTRODUCTION Thank you for purchasing the Whisper Power Sinewave Inverter-Charger. With our state of the art, easy to use design, this product will offer you reliable service by providing True Sinewave AC power for your home, cabin, boat, RV or trailer and recharge your battery automatically when utility AC is available.
  • Page 9: Understanding The Unit

    WhisperPower Inverter / Battery Charger 3. UNDERSTANDING THE UNIT WARNING: It is recommended that all wiring be done by a certified technician or elec- trician to ensure adherence to the applicable electrical safety wiring regulations and installation codes. Failure to follow these instructions can damage the unit and could also result in personal injury or loss of life.
  • Page 10 WhisperPower Inverter / Battery Charger Multi-Function Display Item ① Power indicator ⑨ ② AC Output indicator ③ Status indicator ⑩ ⑩ ④ ⑤ ⑥ ⑦ ⑧ ⑨ Display Panel socket ⑩ BTS port Typical Wiring Block Diagram of Inverter-Charger: A Battery Bank •...
  • Page 11 WhisperPower Inverter / Battery Charger B DC Fuse or Circuit Breaker • DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required. 24V 2000W System 24V 3000W System Fuse/Circuit Breaker Rating 150Adc 200Adc • Based on the size of the Battery Bank, determine the overall short circuit current rating of the battery bank from the battery manufacturer.
  • Page 12 WhisperPower Inverter / Battery Charger E Chassis Ground DANGER: The unit chassis has to be grounded properly before use. Never operate the unit without proper grounding. Failure to do so will result in death or serious injury. Thinnest Wire Gauge Used Model Recreation Vehicle Marine...
  • Page 13 WhisperPower Inverter / Battery Charger H AC Output Socket and I AC Output Thermal Breaker: A single AC Output socket is provided for direct AC output from the unit. An overcurrent protective device (thermal breaker) is connected in series with the AC Output Socket to avoid excessive current being drawn from it.
  • Page 14: Installing The Unit

    WhisperPower Inverter / Battery Charger 4. INSTALLING THE UNIT WARNING: Explosion hazard! • DO NOT install the unit near flammable fumes or gases (such as propane tanks or large engines). • AVOID covering the ventilation openings. Always operate unit in an open area. Choosing the location: The unit should only be installed in locations that meet the following requirements: •...
  • Page 15 WhisperPower Inverter / Battery Charger IMPORTANT: Field wiring DC terminals tightening torque 12-13 Nm • Connect a negative DC input cable between the unit DC negative terminal and battery negative terminal. • Make sure the Disconnect Switch is in the OFF position. Connect a positive DC input cable between the unit DC positive terminal and one terminal of the Disconnect Switch.
  • Page 16 WhisperPower Inverter / Battery Charger For AC Output Hardwire Connections: • Insert the AC Input cable through the AC Output Strain relief b on the unit. • Connect the AC Sub-Panel AC Ground wire to the AC Output Ground terminal x on the unit. If a solid ground wire is used, the wire can be connected directly under the screw head.
  • Page 17: Unit Operation

    WhisperPower Inverter / Battery Charger 5. UNIT OPERATION The unit is preset with factory default settings and will fulfill the basic needs for inverter- charger operation. The display is used to provide information about the unit status and the unit function can be customized through the Display. Once the unit function is customized, the display can be removed if desired, as the unit can run without it.
  • Page 18 WhisperPower Inverter / Battery Charger of the main unit ‘Rx.x’ and then the Display revision levels ‘rx.x’ (where x = any number). - To turn the inverter OFF: press and hold until hearing the beep (in about 1 sec.). Display turns off and the unit cannot be turned on again but after about 3 sec (when hearing the deactivation of the internal relays).
  • Page 19 WhisperPower Inverter / Battery Charger Load Sense (Default): Continuous AC Output when inverter is ON 10 : Continuous AC Output when inverter is ON and AC load is > 10W 15 : Continuous AC Output when inverter is ON and AC load is > 15W 20 : Continuous AC Output when inverter is ON and AC load is >...
  • Page 20 WhisperPower Inverter / Battery Charger Battery : High > 35 °C Temperature (Default): Normal 15 - 35°C : Low < 15°C AC Input 230 Vac Models: Range: 4,6,8,10,12,13,14,16A (Default 16A) Generator Power GPW= Generator Power (AUX in Display)* Factory Select to reset all settings to default.
  • Page 21 WhisperPower Inverter / Battery Charger Battery bar(s) in solid indicating the unit is running in Battery Mode. The bars show estimated remaining battery power. 4 solid bars: Battery is Full Battery 3 solid bars: Battery capacity with 75% remaining Inverter 2 solid bars: Battery capacity with 50% remaining Mode 1 solid bar: Battery capacity with 25% remaining...
  • Page 22 WhisperPower Inverter / Battery Charger Exploring the Unit Settings a) Inverter and Charger Functions AC INPUT AC OUT CHARGE FUNCTIONING COMMENT Bypass Auto Backup Commonly used default setting Backup Bypass For external Backup charger Bypass Manual Backup Requires user intervention Bypass User intervention with external...
  • Page 23 WhisperPower Inverter / Battery Charger c) Battery Disconnect Function Battery Under and Over Voltage Setting Battery Low Disconnect voltage has selectable range: 21.0 - 24.0V (0.2V steps) (Default 21.0V) The Battery Low Disconnect Voltage must be with a minimum of 1.0V below the Battery Low Alarm (BLA) Voltage.
  • Page 24 WhisperPower Inverter / Battery Charger Battery Charging Cycle Charging Voltage Setting: Bulk/Absorption (AbS), Float (FLO) and Recharge (rEC) Battery Type Bulk Voltage (Default) Float Voltage (Default) Recharge Voltage (Default) 27.6-29.6V (28.4V) 26.0-28.0 (27.6V) 25.6-28.0 (25.6V) Flooded 27.6-29.6 & 31.6V (28.8V) 26.0-28.0 (27.0V) 25.6-28.0 (25.6V) 27.6-29.6V (28.6V)
  • Page 25 WhisperPower Inverter / Battery Charger Charging Current Setting: Bulk Stage (bUL), Absorption to Float Stage (AbS) Model Bulk Stage Absorption to Float Stage 24V 3000W 50A, 40A, 30A, 20A, 10A (Default: 50A) 8A, 6A, 5A, 3A, 2A (Default: 5A) 24V 2000W 40A, 30A, 20A, 10A, 5A (Default: 40A) 6A, 5A, 4A, 3A, 2A (Default: 4A) •...
  • Page 26 WhisperPower Inverter / Battery Charger Battery Recharge Timer: The charger will restart a full charging cycle automatically if the float stage is maintained for 7 days. AC Source Circuit Breaker Function AC Source Circuit Breaker Setting 230 Vac Models: Selectable Values: 16, 14, 13, 12, 10, 8, 6, 4A (Default: 16A) This setting limits the total AC current draw from the AC Source during the By-Pass Mode to avoid tripping the AC Source Branch Breaker.
  • Page 27 WhisperPower Inverter / Battery Charger Understanding the Error Codes Code Condition Corrective Action No AC Output. Inverter shutdown due to low Recharge the battery immediately and restart battery voltage. unit. (Battery Mode) Note: E01 will shows for about 30 sec. After 30 sec, Display will turns Off and unit will shutdown completely. - No battery is connected to the unit.
  • Page 28 WhisperPower Inverter / Battery Charger Bad Battery classification: E01 (By-Pass Mode) - Check corrective action in E01 (By-pass Mode) condition has not been solved. AC Charger has and restart the charging process by removing shutdown. and reconnecting the AC Input Source. - Check if there is any heavy DC load connected Other conditions...
  • Page 29: Troubleshooting

    WhisperPower Inverter / Battery Charger 6. TROUBLESHOOTING To troubleshoot the unit, please note the error code displayed on the main unit and review “Understanding the Error Codes” in section 5. PROBLEM POSSIBLE CAUSE/CONDITION SOLUTION The thermal breaker on the unit is Reset the thermal breaker tripped Press and hold the ‘ESCAPE’...
  • Page 30: Specifications

    WhisperPower Inverter / Battery Charger 7. SPECIFICATIONS 24 V Input Model 230VAC 24V Model 61242040 61243050 Running as Inverter AC Output Power 2000W 3000W AC Output Current 8.7A 13.0A AC Surge Power (Peak) 4000W 6000W AC Output Voltage/Frequency 230 VAC / 50Hz AC Output Waveform Sinewave (<3% THD) Nominal DC Input Voltage...
  • Page 31 WhisperPower Inverter / Battery Charger Running as Battery Charger Charging Voltage Range 27.6 - 29.6 VDC Float Voltage Range 26.0 - 28.0 VDC Bulk Charge Current Range 5 - 40 A 10 - 50 A Absorption-Float Current Range 2 - 6 A 2 - 8 A Battery Type Gel, Flooded, AGM, Lithium, Program, Power Supply...
  • Page 32: Warranty

    The warranty for this equipment depends upon the strict application of the instructions appear- ing in this manual. The warranty period for the Whisper Power Centre is 2 years. Refer to the Whisper Power general conditions of sales. 8.1. Exclusion of warranty No warranty claims will be accepted for damage resulting from handling, usage or processing that does not explicitly appear in this manual.
  • Page 33 WhisperPower Inverter / Battery Charger 8.2. Exclusion of liability The placement, commissioning, use, maintenance and servicing of the WP INVERTER CHARGER cannot be the subject of monitoring by WhisperPower. For this reasons we assume no responsibility and liability for damage, costs or losses resulting from an installation that does not conform to the instructions, defective functioning or deficient maintenance.
  • Page 34 WhisperPower Inverter / Battery Charger...
  • Page 35 WhisperPower Inverter / Battery Charger...
  • Page 36 E n j o y G r e e n E n e r g y WhisperPower BV Kelvinlaan 82, 9207 JB Drachten The Netherlands www.whisperpower.com sales@whisperpower.com...