Inverter/ charger

Advertisement

18
WhisperPower Inverter / Battery Charger
of the main unit 'Rx.x' and then the Display revision levels 'rx.x' (where x = any number).
- To turn the inverter OFF: press and hold until hearing the beep (in about 1 sec.). Display
turns off and the unit cannot be turned on again but after about 3 sec (when hearing the
deactivation of the internal relays).
Note: When AC Input is available, this 'Power' button cannot be used to turn OFF the unit.
'Menu/Set' button:
- Press once to view unit setting on display. See more details on
Viewing and Change Unit Setting section.
 and  button:
- The  or  button can be used to scroll through DC Current 'A',
AC Output Power 'KW' and Battery Voltage 'V'.
- Press and hold  and  buttons together for 2 seconds to show
firmware revision numbers.
'Escape' button:
Press and hold for 5 seconds to turn OFF or ON the AC Output Switch
(use this button as an AC Output ON/OFF function for the Output Socket).
Viewing and Change Unit Setting
- When unit is in normal operation mode, Press 'Menu/Set' button once to view unit setting
as listed on the Unit Setting Function Chart.
- The or button can be used to scroll through each unit setting. If a particular setting
needs to be modified, press and hold the 'Menu/Set' button for 5 seconds and the set
parameter will flash on the display. Use the or  button to scroll through the available
settings. Once the desired setting is chosen, press and hold the 'Menu/Set' button until a
beeping sound occur and the new setting is saved.
- Press 'Escape' button once to return back to Normal Operation. (If none of the button is
triggered for about 5 seconds, display will also return back to Normal Operation.
Unit Setting Function Chart
Unit Setting
Display
AC Input
Shore Power
Inverter
230 Vac WP Models: Range: 4,6,8,10,12,13,14,16A. (Default 8 A).
SPW= Shore Power (AC in Display)*
8
: Use as Inverter only. No By-Pass functions.
(Default): Auto Backup. Inverter automatically turns ON when AC
Blackout.
: Manual Backup. When AC Blackout occurs, Inverter has to be
manually turned ON by using the 'Power' button' on either the
Display panel or the 'Power' button on the Main unit
: Inverter function is disabled. No AC backup when AC Blackout.
Description and Available Setting