Download Print this page

Whisper Power Supreme Combi 230V Series User Manual page 28

Inverter/ charger

Advertisement

28
WhisperPower Inverter / Battery Charger
Bad Battery classification: E01 (By-Pass Mode)
condition has not been solved. AC Charger has
shutdown.
E11
Other
conditions
Classification: Battery Voltage remains below 19V
after 15 minutes of charge.
When unit is in By-Pass mode, Internal transfer
E12
switch temperature is high and shutdown occurs.
AC Output GFCI Tripped.
E13
Note: This error function is not effective when Load Sense "LdS' function is in use.
Display panel has communication error.
E14
E15
AC Back Feed to Unit AC Output.
E16
Internal Fault. Unit damage.
AC Input Current withdrawn from the unit is close
E17
to the set AC Circuit Breaker (Cbr) rating.
AC Input Current drawn by unit is beyond the
current rating of the transfer switch. (30A for
E18
120V model, 16A for 230V model). AC Output
Switch is switched off.
Battery temperature sensed by BTS is > 60°C.
E19
Battery charging cycle terminates.
Battery temperature sensed by BTS is > 55 °C and
E20
is close to battery temperature thermal shutdown
Battery temperature sensed by BTS is < 0 °C.
E21
Battery charging cycle terminates.
leading
to
Bad
Battery
- Check corrective action in E01 (By-pass Mode)
and restart the charging process by removing
and reconnecting the AC Input Source.
- Check if there is any heavy DC load connected
to the battery as stated in E01 (By-pass mode).
Restart the charging process.
- Change to a new battery.
Reduce load and check if any ventilation of the
unit is blocked.
Reset the GFCI.
Check RJ12 cable connected between the main
and Display panel.
Check AC Input and AC Output wiring.
Consult Customer Service for assistance.
Reduce AC load. Check the AC Circuit Breaker
(Cbr) rating match with the external AC Input
Source Branch Breaker rating.
Reduce AC Load connected to unit. Press and
hold 'Escape' button for 5 seconds to reset AC
Output Switch to provide AC Output from AC
Input Source.
Cool down the battery. Battery charging cycle
will automatically resume when the temperature
drops to below 50 °C.
Check battery and environmental temperature or
add ventilation to the battery compartment.
Check battery and environmental temperature.
The charging cycle will resume when temperature
increases to > 5 °C.

Advertisement