Advertisement

Load Sense
Battery Low
Disconnect
21.0
Battery Low
Warning
22.0
Battery Low
Recovery
24.0
Audible
Buzzer
AC Charger
Battery Type
Bulk Current
50
Bulk/Absorp-
tion Voltage
28.4
Absorption to
Float Current
5
Float Voltage
27.6
Recharge
Voltage
25.6
WhisperPower Inverter / Battery Charger
(Default): Continuous AC Output when inverter is ON
10 : Continuous AC Output when inverter is ON and AC load is > 10W
15 : Continuous AC Output when inverter is ON and AC load is > 15W
20 : Continuous AC Output when inverter is ON and AC load is > 20W
25 : Continuous AC Output when inverter is ON and AC load is > 25W
Battery Low Disconnect Voltage selectable ranges is 21.0 - 24.0V (0.2V steps)
(Default voltage is set to 21.0V)
Battery Low Warning Voltage selectable ranges is 22.0 – 25.0V (0.2V steps)
(Default voltage is set to 22.0V)
Battery Low Recovery Voltage selectable ranges is 23.0 - 26.0V (0.2V steps)
(Default voltage is set to 24.0V)
(Default): Buzzer is enabled. Unit buzzes when Warning or Error
occurs.
: Buzzer is disabled. Unit does not buzz when Warning and Error occur.
(Default): AC Charger is enabled. Charge battery when AC Input is
available.
: AC Charger is disabled. No battery charging when AC Input is available.
(Default): GEL Battery, default Bulk Charge/Float Voltage is 28.4V/27.6V
: AGM Battery, default Bulk Charge/Float Voltage is 28.6V/26.8V
: Flooded Battery, default Bulk Charge/Float Voltage is 28.8V/27.0V
: Lithium Battery, default Bulk Charge/Float Voltage is 27.8V/27.0V
: Program, default Bulk Charge/Float Voltage is 27.6V/26.4V
: Power Supply Mode, Default Power Supply Voltage 27.6V
24V/3000W Models: Selectable Ranges 50A, 40A, 30A, 20A, 10A (Default 50A)
24V/2000W Models: Selectable Ranges 40A, 30A, 20A, 10A, 5A (Default 40A).
Bulk/Absorption voltage is based on the battery type chosen. All battery
types have selectable ranges of 27.6 – 29.6V. (Default on GEL Battery is
28.4V)
12V/3000W Models: Selectable Range: 8A, 6A, 5A, 3A, 2A (Default 5A).
12V/2000W Models: Selectable Range: 6A, 5A, 4A, 3A, 2A (Default 4A).
Float voltage is based on the battery type chosen. All battery types have
selectable ranges of 26.0 – 28.0V. (Default on GEL Battery is 27.6V)
Battery Recharge Voltage Selectable Range: 25.6 to 28.0V (0.2V step)
(Default on GEL, AGM, Flooded, PGM battery setting is 25.6V and Li
setting is 26.4V).