3
SPECIFICATIONS
3.3
3.3.1
Input signal (Signal direction QD63P6
Device
No.
X00
X01
X02
X03
CH1
X04
X05
X06
X07
X08
CH2
X09
X0A
X0B
X0C
X0D
CH3
X0E
X0F
X10
X11
X12
CH4
X13
X14
X15
X16
X17
CH5
X18
X19
X1A
X1B
X1C
CH6
X1D
X1E
X1F
Downloaded from
ManualsNet.com

I/O Signals to the Programmable Controller CPU

I/O signal list

The following table shows the I/O signals from the QD63P6 to the programmable controller
CPU.
Note that that I/O numbers (X/Y) and I/O addresses mentioned in this and the subsequent
chapters are assumed when the QD63P6 is mounted to the null I/O slot on the main base
unit.
Programmable
controller CPU)
Signal name
Module READY
Counter value large
Counter value coincidence
Counter value small
Reserved
Reserved
Counter value large
Counter value coincidence
Counter value small
Reserved
Reserved
Counter value large
Counter value coincidence
Counter value small
Reserved
Reserved
Counter value large
Counter value coincidence
Counter value small
Reserved
Reserved
Counter value large
Counter value coincidence
Counter value small
Reserved
Reserved
Counter value large
Counter value coincidence
Counter value small
Reserved
Reserved
Error occurrence
search engine
Table 3.4 I/O signal list
Output signal (Signal direction Programmable controller
Device
No.
Y00
Y01
Y02
Y03
CH1
Y04
Y05
Y06
Y07
Y08
CH2
Y09
Y0A
Y0B
Y0C
Y0D
CH3
Y0E
Y0F
Y10
Y11
Y12
CH4
Y13
Y14
Y15
Y16
Y17
CH5
Y18
Y19
Y1A
Y1B
Y1C
CH6
Y1D
Y1E
Y1F
3.3 I/O Signals to the Programmable Controller CPU
CPU
QD63P6)
Signal name
Reserved
Coincidence signal reset command
Preset command
Subtraction count command
Count enable command
Periodic pulse counter start command
Coincidence signal reset command
Preset command
Subtraction count command
Count enable command
Periodic pulse counter start command
Coincidence signal reset command
Preset command
Subtraction count command
Count enable command
Periodic pulse counter start command
Coincidence signal reset command
Preset command
Subtraction count command
Count enable command
Periodic pulse counter start command
Coincidence signal reset command
Preset command
Subtraction count command
Count enable command
Periodic pulse counter start command
Coincidence signal reset command
Preset command
Subtraction count command
Count enable command
Periodic pulse counter start command
Reserved
3.3.1 I/O signal list
1
2
3
4
5
6
7
8
3
- 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd63p6

Table of Contents