Mitsubishi Electric MELSECQ Series User Manual page 34

Multichannel high-speed counter module
Hide thumbs Also See for MELSECQ Series:
Table of Contents

Advertisement

3
SPECIFICATIONS
3
- 12
Downloaded from
ManualsNet.com
(3) Coincidence detection point setting (Un\G6 and 7)
Coincidence detection point change request (Un\G8)
• Write the coincidence detection point setting value to be compared with the
present value A (Un\G10 and 11)/counter present value B (Un\G200 and 201) for
counter.
• When 1 (Change request) is written to the coincidence detection point change
request (Un\G8), the value written to the coincidence detection point setting
(Un\G6 and 7) becomes effective, the QD63P6 writes 0 (No change request) to
the coincidence detection point change request (Un\G8), and then the
coincidence detection point setting is started.
• Setting range of the coincidence detection point setting (Un\G6 and 7) is from
-2147483648 to 2147483647 (32-bit signed binary).
• If 1 (Change request) is not written into the coincidence detection point change
request (Un\G8), the coincidence detection point setting value (Un\G6 and 7)
does not become effective.
• If 1 (Change request) is not written, the setting is not reflected.
Coincidence detection
point change request
(Un\G8)
Coincidence detection
point setting
(Un\G6 and 7)
Figure 3.3 Timing chart for the coincidence detection point setting (Un/G6 and 7)
and coincidence detection point change request (Un\G8)
• For details of the general operation, refer to Section 5.3.
3.4 Buffer Memory Assignment
3.4.2 Details of the buffer memory
search engine
Performed by the QD63P6.
0
1
0
*1
0
100
*1 When the coincidence detection point setting (Un\G6 and 7)
becomes effective, the QD63P6 writes 0 to the coincidence
detection point change request (Un\G8).
1
0
*1
200