4
PROCEDURES AND SETTINGS BEFORE
OPERATION
Phase A
Phase B
External power supply
4
- 12
Downloaded from
ManualsNet.com
(3) Example of wiring with an encoder of voltage output type (5 VDC)
QD63P6
Phase A pulse input +
A19
Phase A pulse input -
B19
240
1/8 W
Phase B pulse input +
A18
Phase B pulse input -
B18
240
1/8 W
5 VDC
0 V
Figure 4.11 Example of wiring with an encoder (5 VDC)
4.4 Wiring
4.4.2 Example of wiring the module and an encoder
search engine
Shielded
OUT
twisted pair cable
GND
Shield
E
Shielded
OUT
twisted pair cable
GND
Shield
E
5 V
0 V
Encoder