Reading Measurement Parameters with the Instrument
After turning on, press the left button briefly to go to the memory location of one of the measurements made, e.g., No. 1. Then,
by briefly pressing the right button, you can scroll through the parameters and other functions (see list below).
Fd : Maximum amplitude of force peak (N)
Td : Force peak duration (s)
Fs : Average value of the static force (N)
Fe : Value of the final force, 5 seconds after initial contact (N)
EN12453 Evaluation: The indication of measured parameters as NOT correct is shown by a flashing of the numerical
parameter accompanied by an acoustic warning (see allowed limits on page 22).
Print function: (only for owners of the FTP thermal printer) with a long press on the right button you can
send the measurement parameters directly to the specific wireless printer. (See also use of the FTP
Thermal Printer on page 13).
N.B. the function is not active if the instrument is connected with the USB cable to the PC.
Displays the date of the measurement with a long press of the right button.
Displays the time of the measurement with a long press of the right button.
Deleting the current single measurement: to proceed, press the right button for a long time, CANC will
flash, then press the right button again for a long time to confirm the deletion.
Function to send measurement parameters to the BlueForce Cloud portal. With a long press on the
right button you can send (again) the parameters of the current measurement.
N.B. the function is not active if the instrument is connected with the USB cable to the PC.
The rE-SEnd function can also be used in the case of a transmission error towards the server. The
warning of a not sent measurement is represented by the lighted dot at the bottom left of the display.