Sharp JW-20CM User Manual page 136

Programmable controller
Table of Contents

Advertisement

[3] Setting procedure
Set top address of relay link area on slave station 01 to 77
Set top address of register link area on slave station 01 to 77
9
V5
V5
V5
① to ⑲ correspond to numbers in page 9·33.
Start slave station PC operation
Turn ON the power of master station PC
Connect support tools
Stop operation of data link (007777
Set top address of the relay link area on the master station
Set data link function (004002
Set number of connecting stations
/number of offset bytes (at memory capacity save function)
Set top address of register link area on master stations
/number of off set bytes (at memory capacity save function)
Set number of sending bytes of the master station relay link
Set number of sending bytes of the slave station 01 to 77
Set number of sending bytes of the master station register link
Set number of sending bytes of the slave station 01 to 77
Set time-out time of SEND/RECEIVE instruction
Set PC model of each station
Select system of each channel in SEND/RECEIVE function
Top address in communication information storage area
when using data memory starting system of SEND/RECEIVE functions
Set connection status of slave stations
Whether the station number information should be output or not
Set top address of flag area
Set detection time of communication error
Writing to EEPROM, start operation (007777
In brackets: See page in chapter 9
Stop PC operation
=00
(8)
=01
(8)
PC operation
End
9
38
·
)
(H)
)
(H)
(at standard function)
(8)
(at standard function)
(8)
relay link
(8)
register link
(8)
=81
)
(8)
(H)
[ 39 ]
[ 39 ]
[ 39 ]
[ 39 ]
[ 39 ]
[ 40 ]
[ 42 ]
[ 42 ]
[ 42 ]
[ 43 ]
[ 44 ]
[ 45 ]
[ 45 ]
[ 46 ]
[ 46 ]
[ 47 ]
[ 48 ]
[ 49 ]
[ 50 ]
[ 50 ]
[ 50 ]
[ 51 ]
[ 51 ]
[ 52 ]
[ 52 ]