10-4 Command
For communication format etc., see network module ZW-98CM/ZW-20AX etc. instruction manual of
host computer side.
Read out relay (1 point unit)
Function
Command code
Writing mode assignment
Operation condition of PC
Assignable address
Set/reset relay (1 point unit)
Function
Command code
Writing mode assignment
Operation condition of PC
Assignable address
10
· "Writing mode assignment" is used to show whether writing to the PC memory has been enabled or
disabled.
0: Writing prohibited
1: Enable writing only to data memory
2: Enable writing all data.
No setting: Enable writing in any mode
Read out ON (01
)/OFF (00
(H)
00
(MRL)
(H)
No
Unrelated
00000 to 15777
(8)
Set (01
)/reset (00
) the specified relay.
(H)
(H)
10
(SRR)
(H)
No
Unrelated
00000 to 15777
(8)
10
4
·
) status of specified relay.
(H)
Letters in brackets are
command name of BASIC
mode.
Letters in brackets are
command name of BASIC
mode.